SATEL ASD-150 

 

15. Press and hold down the test / reset button (designated with the letter A in Figure 2). Alarm should be 

triggered after a few seconds. 

5.  Battery replacement 

The used batteries must not be discarded, but should be disposed of in accordance with the 
existing rules for environment protection. 

The detector power supply battery (CR123A 3 V) ensures operation for about 2 years. If the detector is used as 
part of the ABAX system, low battery information (voltage drop down to 2.75 V) is sent to the ACU-120 / ACU-
270 controller / INTEGRA 128-WRL control panel. If the detector is working in the stand-alone mode, the 
information is presented optically and acoustically – 3 short LED flashes and 3 short sounds every 30 seconds. 
1.  If the detector is used in the ABAX system, start the service mode in the control panel. 
2.  Remove the screw fastening the cover (Fig. 1). 
3.  Turn the cover counter-clockwise (Fig. 2) and remove it (Fig. 3). 

Summary of Contents for ASD-150

Page 1: ... for 5 minutes Pressing the test reset button designated with the letter A in Figure 2 during the alarm will clear the alarm condition and will block the smoke detection function in the detector for 5 minutes Operation as part of the ABAX system Information about alarm is sent by radio to the ACU 120 ACU 270 controller INTEGRA 128 WRL control panel After the causes of alarm have ceased to exist in...

Page 2: ...ny other operations which may cause contamination of the optical chamber are being carried in the facility where the detector is installed the detector must be temporarily covered with a plastic dust cap 4 Maintenance The detectors should be subject to regular checks to ensure they are working correctly Periodic checks should be conducted at least every six months To check whether the detector wor...

Page 3: ...eration for about 2 years If the detector is used as part of the ABAX system low battery information voltage drop down to 2 75 V is sent to the ACU 120 ACU 270 controller INTEGRA 128 WRL control panel If the detector is working in the stand alone mode the information is presented optically and acoustically 3 short LED flashes and 3 short sounds every 30 seconds 1 If the detector is used in the ABA...

Page 4: ... 1999 on radio equipment and terminal telecommunications equipment and the mutual recognition of their conformity The CNBOP PIB Certification Body in Józefów issued the Certificate of Constancy of Performance 1438 CPR 0490 for the construction product ASD 150 Wireless Smoke Detector confirming its compliance with the requirements of EN 54 5 2003 The National Institute of Telecommunications in Wars...

Reviews: