SATEL ASP-200
3
the controller sends a command to the siren (starting / stopping the signaling; blocking /
unblocking the tamper signaling).
ABAX 2
The siren connects to the controller at intervals defined by the “Communication period”
parameter or by using the “ECO” option.
ABAX
The siren connects to the controller every 15 minutes.
If any value different from 0 is programmed for the “Filter” parameter for the ASP-200
siren, the lack of presence will be reported if no transmission from the siren is received
within one hour.
Triggering the signaling
The signaling is triggered:
on receiving a radio command from the controller – optical and acoustic signaling are
controlled independently.
on opening the tamper switch – both optical and acoustic signaling is triggered.
The signaling parameters can be configured remotely (see the ABAX 2 / ABAX controller
manual).
1
Two sound frequencies (1450 Hz/2000 Hz) alternating within
1 second.
2
Sound with rising frequency (from 1450 Hz to 2000 Hz) within
1 second.
3
Sound with smoothly rising and falling frequency (1450 Hz –
2000 Hz – 1450 Hz) within 1 second.
4
Sound with falling frequency (from 2000 Hz to 1450 Hz) within
1 second.
Table 1. Tone types for acoustic signaling.
Blocking the tamper signaling
Opening the tamper switch will not trigger the alarm in the following cases:
for 10 minutes after connecting the battery,
when the ABAX 2 / ABAX system is running in the test mode (the way of starting / ending
the test mode is described in the ABAX 2 / ABAX controller manual),
when the control panel is running in the service mode (the way of starting / ending the
service mode is described in the INTEGRA / VERSA control panel manual).
A few seconds delay may occur between starting the test mode / service mode and blocking
the tamper signaling.
When the tamper signaling is blocked, the leftmost LED is flashing every 3 seconds.
Energy saving mode (ECO)
If you want to prolong the battery life, you can enable in the siren the “ECO” option. When the
“ECO” option is enabled, the periodical communication takes place every 3 minutes. Thus the
battery life can be increased as much as fourfold. The option is only available in the ABAX 2
system. The siren with “ECO” option enabled meets requirements of the EN 50131-1
standard for Grade 2.