4
ASW-200
SATEL
LED indicator
The LED indicates:
ON with colors changing smoothly for 2 seconds
– warm-up after the plug has been
connected to 230 VAC socket,
ON
– when the appliance connected to the plug is turned on (one color is selected or
colors change smoothly depending on the current consumed by the appliance connected
to the plug, where: blue
– minimum value, green – maximum value for appliances up to
300 W, red
– maximum value for appliances up to 2300 W),
3 short red flashes
– remote control was blocked / unblocked by pressing the button on
the enclosure (mode 2),
1 short red flash
– appliance connected to the plug was turned on by pressing the button
when remote control is blocked (mode 2),
2 short red flashes
– appliance connected to the plug was turned off by pressing the
button when remote control is blocked (mode 2),
flashing yellow
– overload (flashing for the entire duration of the trouble),
flashing red
– overheating (flashing for the entire duration of the trouble).
In the factory default settings, the LED indicator is turned off, i.e. it only indicates warm-up
and troubles (overload and overheating). You can turn it on / off when configuring the LED
indicator settings (se
e “Configuring the LED indicator settings”). The LED indicator is also
used in the LED indicator configuration mode.
3. Start-up
The ASW-200 plug should be used indoors, in spaces with normal air humidity. When in use,
the plug must be located within the radio range of the controller / control panel. Thick walls,
metal partitions, etc. will reduce the range of the radio signal. Use the ARF-200 tester to
check the level of radio signal. Place the tester next to the 230 VAC socket. If the radio signal
level indicated by the tester is higher than 40%, the plug can be used there.
1. Connect the plug to the selected 230 VAC socket.
2. Add the ASW-200 controller to the wireless system and configure its settings (see ABAX
/ ABAX 2 controller manual or INTEGRA 128-WRL control panel manual and
“Configuring the LED indicator settings”). The sticker with the serial number required to
register the plug in the system can be found on its enclosure.
In the ABAX system, the plug is identified as ASW-100.
In the VERSA alarm system, you can add and configure the ASW-200 plug by using
the DLOADX program.
Simultaneous operation of the ASW-200 plug by the ABAX 2 and ABAX controller /
INTEGRA 128-WRL alarm control panel is not possible.
3. Check if the plug works properly.
If you need to perform any service or maintenance work on the appliance,
disconnect it from the ASW-200 plug first. Leaving the appliance connected
when the plug is inserted into the 230 VAC socket causes a risk of electric
shock.