background image

ASW-200 

SATEL 

LED indicator 

The LED indicates: 

  ON  with  colors  changing  smoothly  for  2  seconds 

–  warm-up  after  the  plug  has  been 

connected to 230 VAC socket, 

  ON 

–  when  the  appliance  connected  to  the  plug  is  turned  on  (one  color  is  selected  or 

colors change smoothly depending on the current consumed by the appliance connected 
to the plug,  where:  blue 

– minimum value, green – maximum value for appliances up to 

300 W, red 

– maximum value for appliances up to 2300 W), 

  3  short  red flashes 

– remote control was blocked / unblocked by pressing the button on 

the enclosure (mode 2), 

  1 short red flash 

– appliance connected to the plug was turned on by pressing the button 

when remote control is blocked (mode 2), 

  2  short  red  flashes 

–  appliance  connected  to  the  plug  was  turned  off  by  pressing  the 

button when remote control is blocked (mode 2), 

  flashing yellow 

– overload (flashing for the entire duration of the trouble), 

  flashing red 

– overheating (flashing for the entire duration of the trouble). 

In  the  factory  default  settings,  the  LED  indicator  is  turned  off,  i.e.  it  only  indicates  warm-up 
and  troubles  (overload  and  overheating).  You  can  turn  it  on /  off  when  configuring  the  LED 
indicator  settings  (se

e  “Configuring  the  LED  indicator  settings”).  The  LED  indicator  is  also 

used in the LED indicator configuration mode. 

3.  Start-up 

The ASW-200 plug should be used indoors, in spaces with normal air humidity. When in use, 
the plug must be located within the radio range of the controller / control panel. Thick walls, 
metal  partitions,  etc.  will  reduce  the  range  of  the  radio  signal.  Use  the  ARF-200  tester  to 
check the level of radio signal. Place the tester next to the 230 VAC socket. If the radio signal 
level indicated by the tester is higher than 40%, the plug can be used there. 

1.  Connect the plug to the selected 230 VAC socket. 

2.  Add the ASW-200 controller to the wireless system and configure its settings (see ABAX 

/  ABAX 2  controller  manual  or  INTEGRA 128-WRL  control  panel  manual  and 
“Configuring the LED indicator settings”). The sticker with the serial number required to 
register the plug in the system can be found on its enclosure. 

In the ABAX system, the plug is identified as ASW-100. 

In the VERSA alarm system,  you can add and configure the ASW-200 plug by using 
the DLOADX program. 

Simultaneous  operation  of  the  ASW-200  plug  by  the  ABAX 2  and  ABAX  controller  / 
INTEGRA 128-WRL alarm control panel is not possible. 

3.  Check if the plug works properly. 

If  you  need  to  perform  any  service  or  maintenance  work  on  the  appliance, 
disconnect  it  from  the  ASW-200  plug  first.  Leaving  the  appliance  connected 
when  the  plug  is  inserted  into  the  230  VAC  socket  causes  a  risk  of  electric 
shock. 

Summary of Contents for ASW-200

Page 1: ...ASW 200 Smart plug EN Firmware version 1 00 asw 200_en 11 21 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 20 www satel eu...

Page 2: ...rket after 13 August 2005 The device meets the technical regulations of the Eurasian Customs Union SATEL aims to continually improve the quality of its products which may result in changes in their te...

Page 3: ...iption 2 Radio communication 3 Operating modes 3 Protection against overload and overheating 3 LED indicator 4 3 Start up 4 4 Configuring the LED indicator settings 5 Starting configuration mode 5 Con...

Page 4: ...up to 2300 W Relay switched on when the voltage is at the zero cross point Encrypted two way radio communication in the 868 MHz 915 MHz frequency band AES standard Transmission channel diversity 4 cha...

Page 5: ...to turn ON OFF the appliance connected to the plug Information about the appliance state is sent to the controller control panel mode 2 remote or manual control but with option to manually block the r...

Page 6: ...icator is also used in the LED indicator configuration mode 3 Start up The ASW 200 plug should be used indoors in spaces with normal air humidity When in use the plug must be located within the radio...

Page 7: ...changing its color smoothly from blue to red see Configuring Configuring 1 Keep pressing the button on the plug enclosure to select the indication mode The LED indicator shows which indication mode i...

Page 8: ...6 ASW 200 SATEL Dimensions ASW 200 E 45 x 67 mm ASW 200 F 45 x 70 mm Weight ASW 200 E 60 g ASW 200 F 61 g...

Reviews: