ZONE EXPANDER 

CA-64 E

 

ca64e_en 08/08 

The CA-64 E expander is dedicated to interfacing with  INTEGRA series or CA-64 
alarm control panels. It allows extension of the alarm system by eight zones having 
identical features as the zones of the control panel main board. Additionally, the 
expander supports vibration and roller shutter motion detectors. This manual applies 
to the expander with electronics version 2.1 and firmware version 2.0 (or newer). 

1.  Description of electronics board 

 

Z1 COM Z2

Z3

Z4

Z5

Z6

Z7

Z8

COM

COM

COM

TMP

COM

CLK

DAT

+12V

+12V

ADRES
12345

STATUS

1

2

 

 

Fig. 1. Schematic view of the expander electronics board. 

 

Legend: 
1 – LED SATUS to indicate the process of communication between control panel 

and expander: 

  blinking – data exchange with the panel; 

 ON – no data exchange with the panel (the module and the control panel 

connecting wire is damaged, identification of module is not carried out or the 
STARTER program is started in the control panel); 

2 – package of DIP switches designed for setting individual address of the module 

and for selecting the type of supported detectors (see: 

DIP

 SWITCHES

). 

Description of the terminals: 

Z1…Z8 - 

zones 

COM – 

common 

ground 

TMP 

–  module tamper detection circuit (NC) – if not used, it should be shorted 

to ground. 

CLKDTA –  expander bus 

Summary of Contents for CA-64 E

Page 1: ...LK DAT 12V 12V ADRES 12345 STATUS 1 2 Fig 1 Schematic view of the expander electronics board Legend 1 LED SATUS to indicate the process of communication between control panel and expander blinking data exchange with the panel ON no data exchange with the panel the module and the control panel connecting wire is damaged identification of module is not carried out or the STARTER program is started i...

Page 2: ...d to one bus This will permit problems to be avoided during extension of the alarm system To determine the type of detectors to be supported and the method of expander identification in the system use the switch 8 If the switch is set to OFF position the expander zones can be programmed as NO NC EOL 2EOL NO or 2EOL NC If the switch 8 is set to ON position the expander zones can be programmed as NO...

Page 3: ...er supply unit or another expander with power supply can be used for this purpose 3 Starting the expander 1 Turn on power supply of the security system The LED indicating communication with the alarm control panel will come on with steady light 2 Call the Expander identification function in the LCD keypad ÆService mode ÆStructure ÆHardware ÆIdentification When the identification is completed the L...

Page 4: ...nstalled may cause considerable changes in the system If such a situation occurs you can restore the previous status by means of the DLOADX program INTEGRA series or the DLOAD64 program CA 64 control panel Open the Hardware tab in the Structure window and click on the expander in which you want to change the zones numeration and then click on the Advanced settings button in the right hand lower co...

Reviews: