4 CA-64E
SATEL
4. Numeration of zones
After completion of the identification procedure, consecutive numbers in the system
will be assigned to the expander zones. The numeration depends on the control panel
size and is also affected by the address set in the expander and the number of bus to
which the expander is connected. The expanders connected to the first expander bus
have priority over those connected to the second expander bus. It should be borne in
mind, when new expanders are being installed in the system. If the address of a new
zone expander is lower or the expander is connected to the bus 1, and a zones
expander was connected to the bus 2, the numeration of zones in the system will be
changed (the new expander will receive the numbers of zones assigned before to the
previously installed expander, and a greater number of expanders installed may
cause considerable changes in the system).If such a situation occurs, you can restore
the previous status by means of the
D
LOAD
X
program (INTEGRA series) or the
D
LOAD
64
program (CA-64 control panel). Open the „Hardware” tab in the „Structure”
window, and click on the expander in which you want to change the zones
numeration, and then click on the „Advanced settings” button in the right-hand lower
corner of the window. A window will be displayed where you can move the expander
position throughout the list, thus changing the numeration of zones. The changes in
the zones numeration introduced in this way will be valid until the identification
procedure in the system is repeated.
5. Technical data
Number of zones ........................................................................................................... 8
Nominal supply voltage ........................................................................... 12 V DC ±15%
Average current consumption ...............................................................................18 mA
PCB dimensions ............................................................................................. 57x80 mm
Weight ...................................................................................................................... 47 g
The latest EC declaration of conformity and product approval certificates
are available for downloading on website www.satel.pl
SATEL sp. z o.o.
ul. Schuberta 79
80-
172 Gda
ń
sk
POLAND