4.  Numeration of zones 

After completion of the identification procedure, consecutive numbers in the system 
will be assigned to the expander zones. The numeration depends on the control panel 
size and is also affected by the address set in the expander and the number of bus to 
which the expander is connected. The expanders connected to the first expander bus 
have priority over those connected to the second expander bus. It should be borne in 
mind, when new expanders are being installed in the system. If the address of a new 
zone expander is lower or the expander is connected to the bus 1, and a zones 
expander was connected to the bus 2, the numeration of zones in the system will be 
changed (the new expander will receive the numbers of zones assigned before to the 
previously installed expander, and a greater number of expanders installed may 
cause considerable changes in the system).If such a situation occurs, you can restore 
the previous status by means of the 

D

LOAD

X

 program (INTEGRA series) or the 

D

LOAD

64

 program (CA-64 control panel). Open the „Hardware” tab in the „Structure” 

window, and click on the expander in which you want to change the zones 
numeration, and then click on the „Advanced settings” button in the right-hand lower 
corner of the window. A window will be displayed where you can move the expander 
position throughout the list, thus changing the numeration of zones. The changes in 
the zones numeration introduced in this way will be valid until the identification 
procedure in the system is repeated. 

5. Technical data 

Number of zones ........................................................................................................... 8 
Nominal supply voltage ........................................................................... 12 V DC ±15% 

Average current consumption ...............................................................................18 mA 
PCB dimensions ............................................................................................. 57x80 mm 

Weight ...................................................................................................................... 47 g 

 

The latest EC declaration of conformity and product approval certificates 

are available for downloading on website   www.satel.pl 

 

 
 

 
 

SATEL sp. z o.o. 

ul. Schuberta 79 

80-

172 Gda

ń

sk

 

POLAND 

tel. + 48 58 320 94 00 

info@satel.pl 

www.satel.pl 

Summary of Contents for CA-64 E

Page 1: ...LK DAT 12V 12V ADRES 12345 STATUS 1 2 Fig 1 Schematic view of the expander electronics board Legend 1 LED SATUS to indicate the process of communication between control panel and expander blinking data exchange with the panel ON no data exchange with the panel the module and the control panel connecting wire is damaged identification of module is not carried out or the STARTER program is started i...

Page 2: ...d to one bus This will permit problems to be avoided during extension of the alarm system To determine the type of detectors to be supported and the method of expander identification in the system use the switch 8 If the switch is set to OFF position the expander zones can be programmed as NO NC EOL 2EOL NO or 2EOL NC If the switch 8 is set to ON position the expander zones can be programmed as NO...

Page 3: ...er supply unit or another expander with power supply can be used for this purpose 3 Starting the expander 1 Turn on power supply of the security system The LED indicating communication with the alarm control panel will come on with steady light 2 Call the Expander identification function in the LCD keypad ÆService mode ÆStructure ÆHardware ÆIdentification When the identification is completed the L...

Page 4: ...nstalled may cause considerable changes in the system If such a situation occurs you can restore the previous status by means of the DLOADX program INTEGRA series or the DLOAD64 program CA 64 control panel Open the Hardware tab in the Structure window and click on the expander in which you want to change the zones numeration and then click on the Advanced settings button in the right hand lower co...

Reviews: