background image

SATEL 

GPRS-T1 

13 

R

 – the field refers to the event code to be sent in the Contact ID format. The additional 

digit in the Contact ID  format indicates whether it is a new event/disarming,  or a  new 
restore/arming. Select this field, if the event code is to denote new restore/arming (click 
on the field twice to select/deselect it). 

Part.

 – the field refers to the event code to be sent in the Contact ID format. Enter in this 

field  the partition number  which will be included in the event message sent  to the 
monitoring station.  

Zone n.

 – the field refers to the event code to be sent in the Contact ID format. Enter in 

this field the zone  number  which will be included in the event message sent to the 
monitoring station. 

Event 

– this field is to be used in case of the Contact ID format. It displays description of 

the event whose code is entered in the  "Code"  field.  A button designated with three 
dots, which opens the editor of Contact ID codes, is also available in the "Event" field. 

Note:  The test transmission will be sent as an event, if the following parameters and options 

are programmed for the monitoring station: 

– 

GPRS  reporting  (see  section  "Starting GPRS reporting")  or  SMS  reporting  (see 
section "Starting SMS reporting") is activated, 

– 

object identifier different from  "0000"  is programmed or  "Obtain  identifier 
automatically" option is enabled, 

– 

reporting format is programmed, 

– 

event code different from "00" for 4/2 format or from "000" for Contact ID format is 
programmed. 

Test transmissions to be sent to telephone numbers  

The table allows to define the form in which the test transmissions will be sent to the 
telephone numbers programmed in the "GSM telephone, Monitoring stations" tab. Click 
twice on the chosen field  to  select/deselect it  (the field is selected if the  "x"  symbol is 
displayed in it). 

SMS

  –  select this field,  if  the converter test transmission is to be sent to the selected 

telephone number in the form of SMS message.  

CLIP 

–  select this field,  if the converter test transmission for the selected telephone 

number is to be realized with the use of CLIP service (the  converter  will dial the 
programmed  number  and  then will be trying for  30  seconds  to  get through 
- the converter telephone number will be displayed in the telephone). 

Note:  Do not answer any call from the  converter,  if  the  CLIP test transmission  is to  be 

effected without incurring any costs. 

CLIP settings 

The table makes it possible to determine in detail how the CLIP test transmissions are to be 
sent to the four telephone numbers programmed in the "GSM telephone, Monitoring stations" 
tab. Click twice on the chosen field to select/deselect it (the field is selected, if "x" symbol is 
displayed in it). 

Acknowledgement 

– select this field if the converter is to wait for the acknowledgement of 

receipt of test transmission using the CLIP service. In order to acknowledge receiving the 
CLIP test transmission, reject the call coming from the converter. 

Retries number

 – if the "Acknowledgement" field is selected, the test transmission with the 

use of CLIP service can be conducted a specified number of times.  Values from 1 to 15 
can be programmed. Acknowledgement of the CLIP test transmission receipt will make the 
module stop repeating such a transmission (e.g. if the test transmission is programmed to 

Summary of Contents for GPRS-T1

Page 1: ...Monitoring Converter GPRS T1 Program version 2 01 gprs t1_en 11 11 SATEL sp z o o ul Schuberta 79 80 172 Gdańsk POLAND tel 48 58 320 94 00 info satel pl www satel eu ...

Page 2: ... that enables GPRS SMS CLIP reporting for control panels with analog telephone line monitoring dialer intended for intruder alarm systems The product is in conformity with the following EU Directives RTTE 1999 5 EC EMC 2004 108 EC LVD 2006 95 EC The product meets the requirements of harmonized standards EN 50130 4 1995 A1 1998 A2 2003 EN 61000 6 1 2007 EN55022 2006 A1 2007 EN 61000 6 3 2007 EN 609...

Page 3: ...ctions the converter makes use of the features offered by the CLIP service which enables identification of the calling party and presentation of its telephone number Thus test transmissions can be generated and sent without incurring any costs whatsoever Fig 1 Basic applications of the converter 1 CONVERTER FEATURES Simulation of telephone monitoring station Receiving reporting codes sent in DTMF ...

Page 4: ...one and an indicator of troubles connected with logging into the GSM network Output for signaling problems with logging into the GSM network Converter configuration locally through the RS 232 TTL port remotely through the GSM network GPRS technology Automatic module restart Power supply with 12 V DC 15 2 DESCRIPTION OF ELECTRONICS BOARD Fig 2 View of converter electronics board Explanations for Fi...

Page 5: ...PIN code F LEDs are blinking logging into GSM network has failed invalid PIN code G LEDs are blinking logging into GSM network has failed SIM card has been blocked after three attempts to use an invalid PIN code PUK code must be used to unblock the SIM card Description of terminals 12V power supply input 12 V DC 15 COM common ground TIP RING terminals for connecting the control panel telephone com...

Page 6: ...2V and COM terminals 4 Connect the computer to the converter RS 232 TTL port see section Local programming through RS 232 TTL port 5 Turn on the converter power supply 6 Using the GPRS SOFT program define PIN code for the SIM card if the card requires entering the PIN code to be installed in the converter 7 Turn off the converter power supply 8 Insert the SIM card into the socket see Fig 4 9 Turn ...

Page 7: ... programmed locally 4 1 LOCAL PROGRAMMING THROUGH RS 232 TTL PORT The serial COM port of the computer must be connected with the RS 232 TTL port on the converter electronics board The cables for making this connection are available as a set designated DB9FC RJ KPL Indicate in the GPRS SOFT program the computer COM port to be used for communication with the converter To do so click on the Configura...

Page 8: ...sh communication between the converter and the computer do the following 1 Start the GPRS SOFT program 2 Click on the Configuration button see Fig 6 and explanations for the figure and in the window that will open enter the number of TCP port selected for communication with the converter The number will have to be included in the body of SMS message which will be sent to the converter GSM telephon...

Page 9: ...tton color indicates the current communication status green computer COM port enabled server active gray computer COM port disabled server inactive 9 button for selecting the mode of communication with the converter local programming through the RS 232 port or remote programming with the use of GPRS technology and TCP IP protocol 10 information on the mode of communicating with the converter COMn ...

Page 10: ...ort are indicated in the SMS message Fig 7 GSM telephone Monitoring stations tab GSM telephone PIN SIM card PIN code if the card requires entering the PIN code Note Entering invalid PIN code may result in blocking the SIM card SMS center number telephone number of the Short Message Service Center which delivers SMS messages Entering the number is necessary if the converter is to send SMS messages ...

Page 11: ... to the module If 0 is entered the function will be disabled Monitoring station 1 Monitoring station 2 Notes Using GPRS technology event codes can be sent to the STAM 2 monitoring station or to the SMET 256 converter Communication with the subscriber sending event codes with the use of GPRS technology should be tested by the monitoring station as rarely as possible if a value lower than 1 minute i...

Page 12: ...t identifier Do not enter value 0000 the converter will not be sending test transmissions to the monitoring station Using digit 0 in the identifier is not recommended Obtain identifier automatically select this box if the control panel identifier is to be used by the converter for converter s own test transmissions Enabling this option is not recommended when several identifiers are used by the co...

Page 13: ...he field is available if you select the Custom settings option SMS format The format of SMS messages for SMS reporting must be defined according to the monitoring station requirements The default SMS messages format programmed in the converter corresponds to the factory default settings of the STAM 2 monitoring station program version 1 2 0 or later The symbols used for programming the SMS format ...

Page 14: ...est transmission can be sent to the monitoring stations The method of sending the event code SMS GPRS depends on the rules defined for each monitoring station in the GSM telephone Monitoring stations tab It is necessary to define the event code to be sent Event codes for converter test transmission The table makes it possible to define the codes which will be sent to the monitoring stations for th...

Page 15: ...o define the form in which the test transmissions will be sent to the telephone numbers programmed in the GSM telephone Monitoring stations tab Click twice on the chosen field to select deselect it the field is selected if the x symbol is displayed in it SMS select this field if the converter test transmission is to be sent to the selected telephone number in the form of SMS message CLIP select th...

Page 16: ...hone Monitoring stations tab on the Telephone numbers for messaging and test transmissions list Note If the Reaction to CLIP only when number is on list of telephones for messaging option is not enabled the test transmissions and SMS messages with information on device status for the numbers in the list they will be sent by the converter immediately for the numbers not in the list they can be sent...

Page 17: ...es is also available in the Event field T1 T4 define to which telephone numbers see numbers programmed in the GSM telephone Monitoring stations tab in the Telephone numbers for messaging and test transmissions list and how the messaging about receiving the event code is to be executed You can choose from the following options blank field no messaging s SMS messaging c CLIP service notification sc ...

Page 18: ...rs related to the simulation of monitoring station enter the telephone number defined in the control panel for the monitoring station which is to be simulated by the converter define whether the converter is to simulate a telephone line failure if the GSM telephone fails to log into the GSM network Cut off the telephone line voltage if GSM failure option for events in the Ademco Express or Contact...

Page 19: ...orted by the converter to which telephone numbers and in what way Test transmissions CLIP SMS messaging tab enter the identifier that must be received with the event code so that the converter can effect the CLIP SMS messaging Ident field define the format in which the event code must be received so that the converter can effect the CLIP SMS messaging Format field enter the event code the receipt ...

Page 20: ...Kiss off time 600 ms SIA kiss off Custom settings Kiss off time 100 ms Kiss off delay 100 ms SMS format Event Test transmissions CLIP SMS messaging tab CLIP Reaction to CLIP only when number is on list of tel for messaging the option is enabled CLIP SMS messaging Format 4 2 6 SPECIFICATIONS Supply voltage 12 V DC 15 Current consumption standby 50 mA Current consumption max 220 mA Current carrying ...

Reviews: