2 INT-CR
SATEL
4. Make a hole in the wall for the device cable and run the cable through it.
5. Using wall plugs (anchors) and screws, secure the enclosure base to the wall. Select wall
plugs specifically intended for the mounting surface (different for concrete or brick wall,
different for plaster wall, etc.).
6. Set the device address (see “Address setting”).
7. Replace the cover and secure it with the screw.
8. Connect the wires to the control panel screw terminals according to the table below. If the
distance to the control panel exceeds 300 meters, use an additional power supply to
power the device.
Terminals
Wire
Description
INTEGRA /
INTEGRA Plus
VERSA / VERSA Plus /
VERSA IP
brown
power
+EX / +EX1 / +EX2
AUX / KPD
white
common ground
COM
COM
gray
clock
CK / CK1 / CK2
CLK
green
data
DT / DT1 / DT2
DTA
9. Power on the alarm system.
10. Start the identification function in the control panel (see the control panel installer
manual). The device will be identified as INT-IT.
Address setting
An individual address (different from that in the other devices connected to the control panel
bus) must be set in the device. Depending on the control panel:
INTEGRA / INTEGRA Plus: set an address in the range from 0 to 31,
VERSA / VERSA Plus / VERSA IP: set an address in the range from 16 to 21.
To set the address, use the DIP switches on the device electronics board. The switches have
numbers assigned to them. The number for OFF position is 0. The numbers assigned to the
switches in ON position are presented in the table below. The sum of these numbers is the
address set.
Switch (ON position)
1
2
3
4
5
Number
1
2
4
8
16