background image

2 INT-CR 

SATEL 

4.  Make a hole in the wall for the device cable and run the cable through it. 
5.  Using wall plugs (anchors) and screws, secure the enclosure base to the wall. Select wall 

plugs specifically intended for the mounting surface (different for concrete or brick wall, 
different for plaster wall, etc.). 

6.  Set the device address (see “Address setting”).  
7.  Replace the cover and secure it with the screw. 
8.  Connect the wires to the control panel screw terminals according to the table below. If the 

distance to the control panel exceeds 300 meters, use an additional power supply to 
power the device. 

 

Terminals

 

Wire 

Description 

INTEGRA /  

INTEGRA Plus 

VERSA / VERSA Plus / 

VERSA IP 

  brown 

power 

+EX / +EX1 / +EX2 

AUX / KPD 

  white 

common ground 

COM 

COM 

  gray 

clock 

CK / CK1 / CK2 

CLK 

  green 

data 

DT / DT1 / DT2 

DTA 

 
9.  Power on the alarm system. 
10. Start the identification function in the control panel (see the control panel installer 

manual). The device will be identified as INT-IT. 

Address setting 

An individual address (different from that in the other devices connected to the control panel 
bus) must be set in the device. Depending on the control panel: 

  INTEGRA / INTEGRA Plus: set an address in the range from 0 to 31, 

  VERSA / VERSA Plus / VERSA IP: set an address in the range from 16 to 21. 

To set the address, use the DIP switches on the device electronics board. The switches have 
numbers assigned to them. The number for OFF position is 0. The numbers assigned to the 
switches in ON position are presented in the table below. The sum of these numbers is the 
address set. 
 

Switch (ON position) 

Number 

16 

 
 
 