background image

INT-IORS / INT-ORS 

SATEL 

DAT 

-  data (communication bus). 

CLK 

-  clock (communication bus). 

A, B 

-  RS-485 bus. 

 

Explanations to Fig. 1: 

 LED indicators of the status of individual relays: 

red LED ON 

– the relay is inactive, 

green LED ON 

– the relay is active. 

 LED indicating the status of communication with the control panel: 

ON 

– no communication with the control panel, 

blinking 

– communication with the control panel OK. 

 DIP-switches 

used to configure the expander (see “Configuring the expander

). 

 connector for a SATEL power supply unit (e.g. APS-412). 

4.  Configuring the expander 

Address setting 

An individual address must be set in the expander. It must be different from that in the other devices 
connected  to  the  communication  bus.  To  set  the  address,  use  the  DIP-switches  1-5.  The  switches 
have  numbers  assigned  to  them.  The  number  for  OFF  position  is  0.  The  numbers  assigned  to  the 
switches in ON position are presented in the table 1. The sum of these numbers is the address set. 

 

Switch (ON position) 

Number 

16 

Table 1. 

 

Summary of Contents for INT-IORS

Page 1: ...N rail mounted zone and output expander INT ORS DIN rail mounted output expander EN Firmware version 6 01 int iors_en 08 22 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 ww...

Page 2: ...ions or repairs not authorized by the manufacturer shall void your rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technica...

Page 3: ...tor values 8 programmable relay outputs for control of the electrical devices supplied with 230 VAC Capable of being integrated with a SATEL power supply unit operation in expander with power supply m...

Page 4: ...tches used to configure the expander see Configuring the expander connector for a SATEL power supply unit e g APS 412 4 Configuring the expander Address setting An individual address must be set in th...

Page 5: ...IORS zones depends on the selected type of device see table 2 INT IORS INT IORSPS INT PPPS CA 64 PP support for roller shutter and shock detectors support for Triple EOL configuration INTEGRA Plus pro...

Page 6: ...nder expander w o power supply expander with power supply ON INT ORS INT ORSPS OFF INT O CA 64 O INT OPS CA 64 OPS Table 6 5 Installation and start up Disconnect power before making any electrical con...

Page 7: ...the dedicated expander connector or connect the power leads to the 12 and COM terminals the expander may be powered directly from the control panel from an expander with power supply or from a power s...

Page 8: ...expander 6 Updating the expander firmware 1 Use the RS 485 bus to connect the expander to the ACCO USB converter see the ACCO USB converter manual 2 Connect the ACCO USB converter to the computer USB...