LCD keypad:
“Service mode”
“Structure”
“Hardware”
“Expanders”
“Settings”
[controller name]
“Settings”
[wireless keypad name]
.
4.1.1 Description of parameters and options
Fig. 4. DLOADX
program: keypad settings stored in the ABAX 2 / ABAX controller.
Given in the square brackets are the names of parameters and options presented on the
keypad display.
Wake-up
[Wake up] – the maximum time period for which the keypad can be woken up
automatically. If you enter a value different from 0:
– the keypad will be woken up automatically when an alarm occurs or an entry delay, an
exit delay or an auto-arming delay begins,
– the CHIME from zones will also be signaled when the keypad is in the sleep mode.
If you enter 0, the keypad will not be woken up automatically.
If a value different from 0 is preset for the “Wake-up” parameter, the keypad will
be awaiting for transmissions with information on events. As a result, the
energy consumption will be growing and the battery life will be considerably
reduced.
The keypad is woken up not more frequently than every 30 seconds. If the event that
is to wake up the keypad occurs before the 30 seconds have elapsed since the last
automatic wake-up, the keypad will stay asleep.
Card reader
[Reader] – if this option is enabled, the card reader is supported.
Presence contr.
[Test] – if this option is enabled, the keypad presence is being monitored. If
there is no transmission from the keypad for 20 minutes, missing keypad will be reported.