determine the keypad address, add up the numbers set on particular DIP switches, 
according to Table 1. 

 

Switch 

number 

1 2 3 4 5 

Numerical equivalent 

(DIP switch in ON position)

 

1 2 4 8 16 

Table 1. 

 
 
 
 
 
 
 
 

Figure 3. Addressing examples. 

 
Five switches make it possible to assign addresses to 32 expanders (numbers from 0 
to 31). The addresses of expanders connected to one bus cannot be repeated, but the 
addressing order can be random. It is recommended that consecutive addresses, starting 
from zero, be assigned to expanders and modules connected to one bus. This will allow to 
avoid problems during expansion of the system. 

6. Connect the module supply to the +12V terminal. The keypad supply does not have to be 

provided from the control panel main board. An additional power supply unit or expander 
with power supply can be used for this purpose. Details regarding the cable connections 
are described in the installer's manual for the alarm control panel. 

7. Connect the wires of the door state control sensor to the IN and COM terminals. 
8. If the keypad is to serve as a code lock, connect the wires to control the electromagnetic 

door lock (or another device) to the NO terminals. 

9. Close the casing. 

3.  Starting the Partition keypad  

1. Switch on the alarm system power supply. 
2. Call the „

Expander identification

 

function (

Á

Service mode; 

Á

Structure; 

Á

Hardware) from 

the LCD keypad. After identification, all the settings have either the value of zero or „none”, 
and the options are inactive. No acknowledgement when pressing the keys makes one 
think that the module fails to respond to entering a code. 

Note: 

During the identification process, the control panel saves in the module memory 
a special (16-bit) number, used for checking the module presence in the system. 
Replacement of the module with another one (even having the same address set on 
the switches) without a new identification, will result in triggering the alarm (module 
tamper - verification error). 

3.  Using the LCD keypad or DLOADX / DLOAD64 program, configure the keypad functions 

and define the users authorized to use the given partition keypad. 

4.  Quit the service mode or the communication session with PC and save the data in the 

FLASH memory. 

address: 6 

address: 22 

Summary of Contents for INT-S-BL

Page 1: ...temporary automatically activated mode backlight and LED indicators LED designation ALARM red color steady light indicates an alarm in the keypad controlled partition while blinking indicates that an...

Page 2: ...eypad 3 tamper contact The spring should be pressed against the wall 4 buzzer Figure 2 Schematic view of the keypad electronics board 2 Installation and Connection of the Module Note Prior to hookup o...

Page 3: ...ol sensor to the IN and COM terminals 8 If the keypad is to serve as a code lock connect the wires to control the electromagnetic door lock or another device to the NO terminals 9 Close the casing 3 S...

Page 4: ...nt of the keypad to a partition selected from the list Lock feature the option available in the LCD keypad its activation provides access to the Lock submenu Lock DLOADX Lock feature DLOAD64 its activ...

Page 5: ...y contacts NO the NO contacts are normally open they close on activating the relay during its active state NC the N contacts are normally closed they open on activating the relay during its active sta...

Page 6: ...ling the countdown of the auto arming delay in the partition it has been assigned to Access code signaling hardware enabling this option will activate the signaling of code entry acknowledgement which...

Page 7: ...ive not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 5 Technical Data Nominal supply voltage 15 1...

Page 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Reviews: