MULTIFUNCTIONAL KEYPAD 

WITH PROXIMITY CARD READER

INT-SCR-BL 

int-scr_en 06/12 

The INT-SCR-BL multifunctional keypad with proximity card 
reader can operate as: 

partition keypad

 – a device supported by the CA-64 alarm 

control panel, as well as INTEGRA control panels with 
any firmware version, and identified as INT-S/SK. It is 
designed to control arming of one partition. The device 
makes it possible to execute the functions of access 
control and electromagnetic door lock operation. 
It enables changing the user code and calling the control 
functions for outdoor devices, and identifies users by 
their access code. 

partition keypad

 

with proximity card reader

 – a device 

supported by the INTEGRA control panels with firmware 
version 1.05 or later and identified as INT-SCR. 
It performs identical functions as the partition keypad, 
but allows the users to use proximity cards. 

entry keypad

 – a device supported by the INTEGRA 

control panels with firmware version 1.05 or later and 
identified as INT-ENT. The main task of the entry 
keypad is activation of the delay in the partition for the 
zones with reaction type 

3. I

NTERIOR DELAYED

. The time 

period during which these zones will act as delayed 
ones is programmable for the keypad. After expiry of the 
programmed time, the interior delayed zones again act 
as instant ones, unless the partition is disarmed. 

Design of the keypad enables it to be installed outdoors. 
The device is additionally equipped with a bell button to 
control the OC type low-current output. Press the button to 
short the output to the common ground. 
This manual applies to the module with electronics version 
1.4 and firmware version 2.01 (or later). 

1.  Description of the Keypad 

The partition keypad has 13 keys with permanent or 
temporary (automatically activated) mode backlit and LED 
indicators: 

Fig. 1. INT-SCR-BL multifunctional

keypad. 

 

ALARM

 

(red color), 

 - 

ARMED 

(green color), 

 

TROUBLE

 (yellow color). 

Information conveyed by means of the LED indicators depends on the keypad operating mode. 
Alternative blinking of all the LEDs (from the left to the right) indicates lack of communication between 
the keypad and the control panel. This situation may take place when the STARTER program is 
running in the control panel, or when the cable connecting the keypad and the control panel is 
damaged. 
 

Summary of Contents for INT-SCR-BL

Page 1: ...f the delay in the partition for the zones with reaction type 3 INTERIOR DELAYED The time period during which these zones will act as delayed ones is programmable for the keypad After expiry of the pr...

Page 2: ...erminals of the expander bus on the control panel PCB 5 Connect the door status control detector to the brown and blue cables If the door status is not to be controlled connect the brown cable to the...

Page 3: ...d the LED designated ARMED will start blinking 6 Select the operating mode by pressing in turn and partition keypad with proximity card reader INT SCR and entry keypad INT ENT and partition keypad INT...

Page 4: ...e shown at some of the functions Name option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows SERVICE MODE STRUCTURE HARDWARE EXPANDERS NA...

Page 5: ...enabled ster users Users this function defines master users users authorized to use the given keypad Alarms FIRE a key triggers the fire alarm e AUX alarm pressing and holding down for approx 3 secon...

Page 6: ...anel and the partition keypad user No the keypad provides no information on execution of or refusal to execute an operation Sound the keypad provides information on execution of or refusal to execute...

Page 7: ...a computer with the DLOADX program Described below are settings and options available for programming Name option to give an individual 16 character name to the module This option can be accessed in t...

Page 8: ...code is entered or the card is read in After expiry of the programmed time the interior delayed zones will again act as instant ones unless the partition is disarmed No auto reset after 3 tampers you...

Reviews: