authorized to disarm the partition). The zones of the blocked partition will not trigger the burglary 
alarm. The blocking duration is defined individually for each user using the 

T

EMPORARY 

PARTITION BLOCKING 

code type and for the partition (

B

LOCKED FOR GUARD ROUND

). 

Guard round control

 – entering the guard code ended with 

 or 

 key will be recorded as 

completion of the round.

 

Changing access code

 – the user code can be changed using the keypad. 

Signaling 

Alarm signal 

– the keypad will signal the partition alarm acoustically throughout the global alarm 

duration. 

Alarm signal (until canceled / latch)

 – the keypad will signal the partition alarm acoustically until 

the alarm is cleared. 

Signaling entry delay 

– the keypad is acoustically signaling the entry delay countdown. 

Signaling exit delay 

– the keypad is acoustically signaling the exit delay countdown. 

Auto-Arm delay countdown 

– the keypad is acoustically signaling the auto-arming delay time for 

the partition. 

Access code signaling (hardware) 

– the keypad itself, independently of the control panel, will 

audibly acknowledge entering the access code. This signaling is useful if there is a delay 
between the code entry and the audible information generated after verification of the code by 
the control panel. Option is available only in the INTEGRA control panel. 

CHIME

 - the module is acoustically signaling violation of the zones having the 

CHIME

 IN MODULE

 

option enabled and belonging to the same partition as the module. 

Confirming

 – this option defines the way of communication between the control panel and the 

partition keypad user: 

No

 – the keypad provides no information on execution of or refusal to execute an operation. 

Sound

 – the keypad provides information on execution of or refusal to execute an operation by 

means of beeps (see: control panel user manual). 

Backlight

 – the keypad provides information on execution of or refusal to execute an operation by 

means of blinking of key backlight (see: control panel user manual). 

Backlight

 – defines the mode of keypad illumination. 

No

 – keypad backlit disabled. 

Auto

 – keypad backlit goes on automatically on pressing any key; the function has additional 

options (submenu 

A

UTO

-

BACKLIGHT 

in LCD keypad): 

 

no auto-backlight

 – illumination only activated by pressing one of the keys, 

 

zone violation

 – backlit activated by pressing a key or by violation of the indicated zone, 

 

entry delay, part

– backlit activated by pressing a key or by starting the countdown of entry 

delay time in the indicated partition. 

Note:  Automatic keypad illumination is ON for approx. 40 seconds from the moment of its 

activation or from the last press of any key. 

Permanent

 – keypad backlit is permanently “ON”. 

No auto-reset after 3 tampers

 – you can disable the feature limiting to three the number of tamper 

alarms from the expander (the feature prevents the same events from being logged repeatedly and 
applies to the successive uncleared alarms). 

Open door if fire 

[Doors on fire] – the fire alarm can have an effect on unblocking the door: 

 

no 

– fire alarm has no effect on the door blocking, 

 

partition fire alarm 

– fire alarm in the partition will unblock the door controlled by the module, 

 

object fire alarm 

– fire alarm in the object will unblock the door controlled by the module, 

 

fire alarm 

– fire alarm in the system will unblock the door controlled by the module. 

Summary of Contents for INT-SCR-BL

Page 1: ...f the delay in the partition for the zones with reaction type 3 INTERIOR DELAYED The time period during which these zones will act as delayed ones is programmable for the keypad After expiry of the pr...

Page 2: ...erminals of the expander bus on the control panel PCB 5 Connect the door status control detector to the brown and blue cables If the door status is not to be controlled connect the brown cable to the...

Page 3: ...d the LED designated ARMED will start blinking 6 Select the operating mode by pressing in turn and partition keypad with proximity card reader INT SCR and entry keypad INT ENT and partition keypad INT...

Page 4: ...e shown at some of the functions Name option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows SERVICE MODE STRUCTURE HARDWARE EXPANDERS NA...

Page 5: ...enabled ster users Users this function defines master users users authorized to use the given keypad Alarms FIRE a key triggers the fire alarm e AUX alarm pressing and holding down for approx 3 secon...

Page 6: ...anel and the partition keypad user No the keypad provides no information on execution of or refusal to execute an operation Sound the keypad provides information on execution of or refusal to execute...

Page 7: ...a computer with the DLOADX program Described below are settings and options available for programming Name option to give an individual 16 character name to the module This option can be accessed in t...

Page 8: ...code is entered or the card is read in After expiry of the programmed time the interior delayed zones will again act as instant ones unless the partition is disarmed No auto reset after 3 tampers you...

Reviews: