authorized to disarm the partition). The zones of the blocked partition will not trigger the burglary
alarm. The blocking duration is defined individually for each user using the
T
EMPORARY
PARTITION BLOCKING
code type and for the partition (
B
LOCKED FOR GUARD ROUND
).
Guard round control
– entering the guard code ended with
or
key will be recorded as
completion of the round.
Changing access code
– the user code can be changed using the keypad.
Signaling
Alarm signal
– the keypad will signal the partition alarm acoustically throughout the global alarm
duration.
Alarm signal (until canceled / latch)
– the keypad will signal the partition alarm acoustically until
the alarm is cleared.
Signaling entry delay
– the keypad is acoustically signaling the entry delay countdown.
Signaling exit delay
– the keypad is acoustically signaling the exit delay countdown.
Auto-Arm delay countdown
– the keypad is acoustically signaling the auto-arming delay time for
the partition.
Access code signaling (hardware)
– the keypad itself, independently of the control panel, will
audibly acknowledge entering the access code. This signaling is useful if there is a delay
between the code entry and the audible information generated after verification of the code by
the control panel. Option is available only in the INTEGRA control panel.
CHIME
- the module is acoustically signaling violation of the zones having the
CHIME
IN MODULE
option enabled and belonging to the same partition as the module.
Confirming
– this option defines the way of communication between the control panel and the
partition keypad user:
No
– the keypad provides no information on execution of or refusal to execute an operation.
Sound
– the keypad provides information on execution of or refusal to execute an operation by
means of beeps (see: control panel user manual).
Backlight
– the keypad provides information on execution of or refusal to execute an operation by
means of blinking of key backlight (see: control panel user manual).
Backlight
– defines the mode of keypad illumination.
No
– keypad backlit disabled.
Auto
– keypad backlit goes on automatically on pressing any key; the function has additional
options (submenu
A
UTO
-
BACKLIGHT
in LCD keypad):
no auto-backlight
– illumination only activated by pressing one of the keys,
zone violation
– backlit activated by pressing a key or by violation of the indicated zone,
entry delay, part.
– backlit activated by pressing a key or by starting the countdown of entry
delay time in the indicated partition.
Note: Automatic keypad illumination is ON for approx. 40 seconds from the moment of its
activation or from the last press of any key.
Permanent
– keypad backlit is permanently “ON”.
No auto-reset after 3 tampers
– you can disable the feature limiting to three the number of tamper
alarms from the expander (the feature prevents the same events from being logged repeatedly and
applies to the successive uncleared alarms).
Open door if fire
[Doors on fire] – the fire alarm can have an effect on unblocking the door:
no
– fire alarm has no effect on the door blocking,
partition fire alarm
– fire alarm in the partition will unblock the door controlled by the module,
object fire alarm
– fire alarm in the object will unblock the door controlled by the module,
fire alarm
– fire alarm in the system will unblock the door controlled by the module.