Backlight

 – the module provides information on execution of or refusal to execute an operation by 

means of blinking of key backlight (see: control panel user manual). 

Backlight

 – defines the mode of keypad illumination. 

No

 – keypad backlighting disabled. 

Auto

 – keypad backlighting goes on automatically on pressing any key. 

Note:  Automatic keypad illumination is ON for approx. 40 seconds from the moment of its 

activation or from the last press of any key. 

Permanent

 – keypad backlighting is permanently “ON”. 

Delay activation time 

– the time period during which the zones with reaction type 3

. I

NTERIOR 

DELAYED

 (belonging to the partition to which the keypad is assigned) will act as delayed ones. 

The countdown will start running after the code is entered or the card is read in. After expiry of the 
programmed time, the interior delayed zones will again act as instant ones, unless the partition is 
disarmed. 

No auto-reset after 3 tampers

 – you can disable the feature limiting to three the number of tamper 

alarms from the expander (the feature prevents the same events from being logged repeatedly and 
applies to the successive uncleared alarms). 

8.  Specifications 

Supply voltage ..................................................................................................................12 V DC ±15% 
Standby current consumption...................................................................................................... 105 mA 
Maximum current consumption ................................................................................................... 125 mA 
BELL output load capacity............................................................................................................. 30 mA 
Reader operating frequency ....................................................................................................... 125 kHz 
Relay contacts rating (resistive load)..................................................................................2 A / 24 V DC 
Environmental class ............................................................................................................................. IV 
Operating temperature range ............................................................................................... -25...+55 °C 
Maximum humidity........................................................................................................................ 93±3% 
Dimensions.................................................................................................................. 47 x 158 x 24 mm 
Cable length .......................................................................................................................................4 m 
Weight .............................................................................................................................................297 g 
 
 

The declaration of conformity may be consulted at www.satel.eu/ce 

 
 
 
 
 

SATEL sp. z o.o. 

ul. Schuberta 79 

80-172 Gda

ń

sk 

POLAND 

tel. + 48 58 320 94 00 

info@satel.pl 

www.satel.eu 

 

Summary of Contents for INT-SCR-BL

Page 1: ...f the delay in the partition for the zones with reaction type 3 INTERIOR DELAYED The time period during which these zones will act as delayed ones is programmable for the keypad After expiry of the pr...

Page 2: ...erminals of the expander bus on the control panel PCB 5 Connect the door status control detector to the brown and blue cables If the door status is not to be controlled connect the brown cable to the...

Page 3: ...d the LED designated ARMED will start blinking 6 Select the operating mode by pressing in turn and partition keypad with proximity card reader INT SCR and entry keypad INT ENT and partition keypad INT...

Page 4: ...e shown at some of the functions Name option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows SERVICE MODE STRUCTURE HARDWARE EXPANDERS NA...

Page 5: ...enabled ster users Users this function defines master users users authorized to use the given keypad Alarms FIRE a key triggers the fire alarm e AUX alarm pressing and holding down for approx 3 secon...

Page 6: ...anel and the partition keypad user No the keypad provides no information on execution of or refusal to execute an operation Sound the keypad provides information on execution of or refusal to execute...

Page 7: ...a computer with the DLOADX program Described below are settings and options available for programming Name option to give an individual 16 character name to the module This option can be accessed in t...

Page 8: ...code is entered or the card is read in After expiry of the programmed time the interior delayed zones will again act as instant ones unless the partition is disarmed No auto reset after 3 tampers you...

Reviews: