5. Using the DIP-switches, set the keypad address. The address should be set by means of 

the switches 1 to 5 (the status of the other switches is irrelevant). This address must differ 
from those of the other modules connected to the control panel expander bus. In order to 
determine the keypad address, add up the numbers set on particular DIP switches, 
according to Table 1. 

 

Switch 

number 

1 2 3 4 5 

Numerical equivalent 

(DIP switch in ON position)

 

1 2 4 8 16 

Table 1. 

 
 
 
 
 
 
 
 

Figure 3. Addressing examples. 

 
Five switches make it possible to assign addresses to 32 expanders (numbers from 0 
to 31). The addresses of expanders connected to one bus cannot be repeated, but the 
addressing order can be random. It is recommended that consecutive addresses, starting 
from zero, be assigned to expanders and modules connected to one bus. This will allow to 
avoid problems during expansion of the system. 

6. Connect the module supply to the +12V terminal. The keypad supply does not have to be 

provided from the control panel main board. An additional power supply unit or expander 
with power supply can be used for this purpose. Details regarding the cable connections 
are described in the installer's manual for the alarm control panel. 

7. Connect the wires of the door state control sensor to the IN and COM terminals. 
8. If the keypad is to serve as a code lock, connect the wires to control the electromagnetic 

door lock (or another device) to the NO terminals. 

9. Close the casing. 

4.  Starting the partition keypad  

1. Switch on the alarm system power supply. 
2. Call the „

Expander identification

 

function (

Á

Service mode; 

Á

Structure; 

Á

Hardware) from 

the LCD keypad. After identification, all the settings have either the value of zero or „none”, 
and the options are inactive. No acknowledgement when pressing the keys makes one 
think that the module fails to respond to entering a code. 

Note: 

During the identification process, the control panel saves in the module memory 
a special (16-bit) number, used for checking the module presence in the system. 
Replacement of the module with another one (even having the same address set on 
the switches) without a new identification, will result in triggering the alarm (module 
tamper - verification error). 

3.  Using the LCD keypad or DLOADX / DLOAD64 program, configure the keypad functions 

and define the users authorized to use the given partition keypad. 

address: 6 

address: 22 

Summary of Contents for INT-SK-GR

Page 1: ...lled partition while blinking indicates that an alarm was triggered in the partition ARMED green color steady light indicates that the partition to which the keypad is assigned has been armed Blinking...

Page 2: ...d COM common ground 12V power supply input CLK DTA expander bus 3 Installation and connection of the module The partition keypad is designed for indoor installation It may be mounted either directly t...

Page 3: ...n be used for this purpose Details regarding the cable connections are described in the installer s manual for the alarm control panel 7 Connect the wires of the door state control sensor to the IN an...

Page 4: ...ns Figure 4 DLOADX program window with partition keypad options Name the option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows Service m...

Page 5: ...or reconnection of the IN input to common ground but not longer than for the relay ON time Relay ON time the time period during which the relay is active Duration of the relay ON time can be from 1 to...

Page 6: ...acoustic alarm signaling in the given partition until the alarm is cleared Signaling entry delay acoustic signaling of the countdown of entry delay time Signaling exit delay acoustic signaling of the...

Page 7: ...not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 6 Technical data Nominal supply voltage 15 12V D...

Page 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Reviews: