background image

INT-SK-GR SATEL 

 

7

Permanent

 - keypad backlighting is permanently "ON". 

No auto-reset after 3 tampers

 - each expander automatically disables the tamper alarming 

in the given expander after three consecutive (not cleared) tamper alarms. This 
prevents multiple recording of the same events in the control panel memory. The option 
allows this feature to be disabled. 

6. Technical data 

Nominal supply voltage (±15%) .....................................................................................12V DC 
Maximum current consumption.........................................................................................65mA 
Average current consumption ...........................................................................................19mA 
Maximum voltage switched over by relay ............................................................................24V 
Maximum current switched over by relay...............................................................................2A 
Dimensions (length x height x width) ..................................................................144x80x27mm 

 

Summary of Contents for INT-SK-GR

Page 1: ...lled partition while blinking indicates that an alarm was triggered in the partition ARMED green color steady light indicates that the partition to which the keypad is assigned has been armed Blinking...

Page 2: ...d COM common ground 12V power supply input CLK DTA expander bus 3 Installation and connection of the module The partition keypad is designed for indoor installation It may be mounted either directly t...

Page 3: ...n be used for this purpose Details regarding the cable connections are described in the installer s manual for the alarm control panel 7 Connect the wires of the door state control sensor to the IN an...

Page 4: ...ns Figure 4 DLOADX program window with partition keypad options Name the option to give an individual 16 character name to the module This option can be accessed in the LCD keypad as follows Service m...

Page 5: ...or reconnection of the IN input to common ground but not longer than for the relay ON time Relay ON time the time period during which the relay is active Duration of the relay ON time can be from 1 to...

Page 6: ...acoustic alarm signaling in the given partition until the alarm is cleared Signaling entry delay acoustic signaling of the countdown of entry delay time Signaling exit delay acoustic signaling of the...

Page 7: ...not cleared tamper alarms This prevents multiple recording of the same events in the control panel memory The option allows this feature to be disabled 6 Technical data Nominal supply voltage 15 12V D...

Page 8: ...est EC declarations of conformity and certificates are available for downloading on the website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www s...

Reviews: