background image

10 

INT-SK 

SATEL 

  clear alarm, 

  gain access (turn on the expander relay output), 

  toggle the state of “25. BI switch” type outputs, 

  turn on the “24. MONO switch” type outputs, 

  confirm the guard round, 

  temporary block the partition, 

  unblock access to cash machine. 

You can start two or more functions at the same time (e.g. disarming, alarm clearing and 
gaining access). 

4.4.3  Quick arming 

The installer may permit arming without using the code. 

1.  To select the arming mode, press one of the keys: 

 - full arming, 

 - full  bypasses, 

 - arming without interior, 

 - arming without interior and without entry delay. 

2.  Press 

. This will start the partition arming procedure (if the exit delay is 0, the partition 

will be armed instantly). 

4.4.4  Triggering the alarm from keypad 

The installer can permit triggering alarms from the keypad. To trigger  an alarm, do the 
following: 

fire alarm

 – press and hold down 

 for about 3 seconds, 

medical (auxiliary) alarm

 – press and hold down 

 for about 3 seconds, 

panic alarm

 – press and hold down 

 for about 3 seconds. The installer defines whether 

the audible or silent panic alarm will be triggered. 

4.4.5  Silencing alarm at the partition keypad 

Press any number key to silence the keypad sounder during an alarm condition for about 40 
seconds. 

4.4.6  Code changing 

You can change your code if the “Changing access code” option is enabled. 

1.  Press and hold the 

 key for about 3 seconds. 

2.  When the 

 and 

 LEDs start flashing alternately, enter the old code and press 

3.  When the 

  and 

  LEDs start flashing  alternately, enter the new code and press 

4.5  Impact of the EN 50131 standard on keypad use 

If the control panel has been configured in accordance with the requirements of Standard 
EN 50131 for Grade 2 (INTEGRA) or Grade 3 (INTEGRA Plus): 

  the keypad does not signal alarms, 

  the 

 LED indicates alarms only after entering the code, 

  flashing of the 

 LED indicates a trouble, bypassed zones or an alarm, 

Summary of Contents for INT-SK

Page 1: ...INT SK Partition keypad Firmware version 2 02 int sk_en 08 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Page 2: ...rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the change...

Page 3: ...indicators 8 4 2 Sound signaling 8 4 2 1 Beeps generated when operating 8 4 2 2 Signaling events 8 4 3 Code 9 4 4 Available functions 9 4 4 1 Code 9 4 4 2 Code 9 4 4 3 Quick arming 10 4 4 4 Triggering...

Page 4: ...earing in partition Capability of triggering alarm from the keypad Single door control relay output for control of electric strike electromagnetic lock or another door actuator door status input NC Co...

Page 5: ...cable The wires must be run in one cable 8 If the partition keypad is to control an electric strike electromagnetic lock or another door actuator connect this device to the NO terminals as shown in Fi...

Page 6: ...ation bus 3 Configuring The keypad settings you can configure using DLOADX program Structure window Hardware tab Expansion modules branch keypad name LCD keypad Service mode Structure Hardware Expande...

Page 7: ...door status input is disconnected from common ground however not longer than for the Relay ON time Fixed ON time OFF if door closed ON close off the relay output will be turned on until the door is c...

Page 8: ...and press Access if armed Code in arm if the option is enabled the users can gain access turn the relay output on when the partition is armed If the option is disabled the users cannot gain access wh...

Page 9: ...ode entered if this option is enabled the partition keypad will confirm with a single beep that the code has been entered The signaling is useful when there is a delay between entering the code and th...

Page 10: ...it with flashing of the keys backlight see Configuring 1 short beep any number key is pressed or the code is used 2 short beeps acceptance of the first code during two code arming disarming 3 short b...

Page 11: ...not make your code available to other people 4 4 Available functions Availability of the functions depends on type and rights of the user keypad settings partition state If you use the code to arm dis...

Page 12: ...ire alarm press and hold down for about 3 seconds medical auxiliary alarm press and hold down for about 3 seconds panic alarm press and hold down for about 3 seconds The installer defines whether the...

Page 13: ...delay countdown there is a violated zone in partition which was not violated when the arming procedure was started there is a trouble which did not exist when the arming procedure was started 5 Specif...