10
INT-SK
SATEL
•
clear alarm,
•
gain access (turn on the expander relay output),
•
toggle the state of “25. BI switch” type outputs,
•
turn on the “24. MONO switch” type outputs,
•
confirm the guard round,
•
temporary block the partition,
•
unblock access to cash machine.
You can start two or more functions at the same time (e.g. disarming, alarm clearing and
gaining access).
4.4.3 Quick arming
The installer may permit arming without using the code.
1. To select the arming mode, press one of the keys:
- full arming,
- full bypasses,
- arming without interior,
- arming without interior and without entry delay.
2. Press
. This will start the partition arming procedure (if the exit delay is 0, the partition
will be armed instantly).
4.4.4 Triggering the alarm from keypad
The installer can permit triggering alarms from the keypad. To trigger an alarm, do the
following:
fire alarm
– press and hold down
for about 3 seconds,
medical (auxiliary) alarm
– press and hold down
for about 3 seconds,
panic alarm
– press and hold down
for about 3 seconds. The installer defines whether
the audible or silent panic alarm will be triggered.
4.4.5 Silencing alarm at the partition keypad
Press any number key to silence the keypad sounder during an alarm condition for about 40
seconds.
4.4.6 Code changing
You can change your code if the “Changing access code” option is enabled.
1. Press and hold the
key for about 3 seconds.
2. When the
and
LEDs start flashing alternately, enter the old code and press
.
3. When the
and
LEDs start flashing alternately, enter the new code and press
.
4.5 Impact of the EN 50131 standard on keypad use
If the control panel has been configured in accordance with the requirements of Standard
EN 50131 for Grade 2 (INTEGRA) or Grade 3 (INTEGRA Plus):
•
the keypad does not signal alarms,
•
the
LED indicates alarms only after entering the code,
•
flashing of the
LED indicates a trouble, bypassed zones or an alarm,