To set the address, use the DIP switches on the electronics board. The switches have
numbers assigned to them. The number for OFF position is 0. The numbers assigned to the
switches in ON position are presented in the table 1. The sum of these numbers is the
address set.
Switch (ON position)
1
2
3
4
5
Number
1
2
4
8
16
Table 1.
Fig. 3. Examples of partition keypad address setting.
2.2 Description of terminals
NO
- relay output
IN
- door status input (NC)
COM
- common ground
+12V
- power input
DTA
- data (expander communication bus)
CLK
- clock (expander communication bus)
3. Configuring
The keypad settings you can configure using:
•
DLOADX program:
“Structure” window
“Hardware” tab
“Expansion modules”
branch
[keypad name]
,
•
LCD keypad:
“Service mode”
“Structure”
“Hardware”
“Expanders”
“Settings”
[keypad name]
.
3.1 Description of parameters and options
Names of parameters and options from the DLOADX program are used in this manual.
Shown in square brackets at the description of a parameter or option is the name presented
on the display of the LCD keypad.
Name
– individual name of the device (up to 16 characters).
Partition
– partition operated by the keypad.
Lock
[Lock feature] – if this option is enabled, the keypad can control the access to a single
door (the following parameters are available: “Lock features”, “Relay ON time”, “Max. door
open time” etc.).