Installation of the keypad working in MASTER mode 

1.  Open the keypad enclosure (Fig. 1). The enclosure opening tool is included in the keypad 

delivery set. 

 

2.  Place the enclosure base against the wall and mark the location of mounting holes. 

3.  Drill the holes for wall plugs (screw anchors). 

4.  Install  in  the  wall  a  junction  box  in  which  you  will  place  the  ferrite  ring.  Make  sure  it  is 

placed as close as possible to the keypad. 

5.  Wind the cables around the ferrite ring (Fig. 2), but no more than 3 turns per cable. 

 

6.  Place the ferrite ring inside the junction box. 

7.  Pass the cables through the opening in the enclosure base. 

8.  Using wall plugs (anchors) and screws, secure the enclosure base to the wall. Proper wall 

plugs  must  be  selected  for  the  type  of  mounting  surface  (different  for  concrete  or  brick 
wall, different for plaster wall, etc.). 

9.  Connect the wires of the control panel keypad bus to the DTM, CKM and COM terminals 

(Fig.  3).  If  you  use  the  twisted-pair  type  of  cable,  remember  that  CKM  (clock)  and  DTM 
(data) signals must not be sent through one twisted-pair cable. 