SATEL
INTEGRA 128-WRL
33
Hardwired programmable outputs ............................................................................................ 8
Maximum number of programmable outputs ....................................................................... 128
Power supply outputs .............................................................................................................. 3
Communication buses ......................................................................................................... 1+1
Keypads .......................................................................................................................... up to 8
Expansion modules ...................................................................................................... up to 32
Objects (subsystems) .............................................................................................................. 8
Partitions ................................................................................................................................ 32
Telephone numbers for messaging ....................................................................................... 16
Voice messages .................................................................................................................... 16
Text messages ...................................................................................................................... 64
Users + Masters ............................................................................................................. 240 + 8
Timers .................................................................................................................................... 64
Event log .......................................................................................................................... 21503
Security grade according to EN50131 .......................................................................... Grade 2
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range ................................................................................. -10…+55 °C
Maximum humidity .......................................................................................................... 93±3%
Electronics board dimensions ............................................................................. 192 x 106 mm
Enclosure dimensions (OPU-3P) ............................................................... 324 x 382 x 108 mm
Weight (incl. enclosure and accessories) ........................................................................ 2130 g
8.2 INT-KLCD keypad
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption .......................................................................................... 17 mA
Maximum current consumption ...................................................................................... 101 mA
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range ................................................................................. -10…+55 °C
Maximum humidity .......................................................................................................... 93±3%
Enclosure dimensions .................................................................................. 140 x 126 x 26 mm
Weight ............................................................................................................................... 231 g
8.3 INT-KLCDR keypad
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption .......................................................................................... 60 mA
Maximum current consumption ...................................................................................... 156 mA
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range ................................................................................. -10…+55 °C
Maximum humidity .......................................................................................................... 93±3%
Enclosure dimensions .................................................................................. 140 x 126 x 26 mm
Weight ............................................................................................................................... 236 g
8.4 INT-KLCDL keypad
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption .......................................................................................... 61 mA