28
INT-TSH2
SATEL
4. Specify the test duration (maximum 50 minutes) and tap
.
5. Define, whether violation of the zone is to trigger CHIME in the keypad (if yes, tap any
number key – the following character will be displayed: Y).
6. Tap
. The zone test will start.
7. Depending on the type of tested detector:
– magnetic contact – open and close the door or window protected by the magnetic
contact,
– motion detector – walk through the coverage area of the detector,
– other detectors – follow the manufacturer's directions for the detector testing.
8. Tap the “View results” function to see the test results (see “Review of test results” p. 28).
9. Tap the “Clear results” function to delete the test results.
10.10.4 Review of test results
Tap the “View results” function. The list of tested zones will be displayed. The icon that
indicates the test results is displayed below the zone name:
zone was not violated.
zone was violated.
Information about the status of the tested zones is not refreshed automatically.
If you want to refresh the information, tap the “View results” function again.
10.11 “Settings” screen
Fig. 13. “Settings” screen (example).