background image

2 MDM56 

SATEL 

 

Installation and connection of modem to control panel 

The MDM56 BO modem can be installed in common housing with the control panel or 
individually in the OPU-1A plastic enclosure, much in the same way as other expanders 
without power supply, designed for the same control panels. 
In order to connect the modem to the control panel, follow the procedure below (for details, 
see the installer manual for the respective control panel): 
1.  Using the cable included in the delivery set, connect the modem RS-232 port to the  

control panel RS-232 port. 

2.  Connect the telephone line wires in parallel to the TIP and RING terminals of control 

panel and modem. 

3.  Connect power from the control panel to the +12V and COM terminals. 
4.  Program the control panel settings so as to enable interaction with the external analog 

modem. 

NOTES: 

 

If the DWNL-RS function (programming via RS port) is running in the control panel, switch 
this function off before you proceed to  programming the control panel through the external 
modem. 

 

The modem requires no configuration, as the factory settings ensure interaction with the 
SATEL made INTEGRA and CA-64 control panels. 

Specifications 

Supply voltage ................................................................................................... 12 V DC ±15% 
Mean current consumption.............................................................................................110 mA 
Protocols: ......ITU-T V.90, V.34, V.32bis, V.32., V.23, V.22bis, V.22, Bell 212A, V.21, Bell 103 
Working temperature range (Class II): ..................................................................-10 to +55 °C 
Weight.................................................................................................................................92 g 
 

DECLARATION OF CONFORMITY 

 

Product:  

MDM56 BO – PSTN modem for remote 
uploading/downloading 

Manufacturer: 

SATEL spó

ł

ka z o.o. 

ul. Schuberta 79 
80-172 Gda

ń

sk, POLAND

tel. (+48 58) 320-94-00 
fax. (+48 58) 320-94-01 

Product description

:

 

56kbps multi protocol telephone modem dedicated for remote 

uploading/downloading of SATEL intruder alarm control panels. 

This product meet the essential requirements of the following EU Directives: 

EMC 

89/336/EWG + 91/263/EEC, 92/31/EEC, 93/68/EEC 

R&TTE

 1999/5/EC (network connection, TBR21) 

Following harmonized standards have been applied for conformity assessment: 

EMC: EN 55022:1998; EN 50130-4:1995; EN 61000-4-2/-3/-4/-5/-6 
R&TTE: TBR21(1998) 

Gda

ń

sk, Poland 2006-04-03 

Head of Test Laboratory:  

Micha

ł

 Konarski 

The latest EC declaration of conformity and product certificates can be downloaded from our website 

www.satel.pl

 

 