background image

SATEL 

SP-4006 

The SP-4006 BL siren has the two indicator LEDs situated on the opposite ends of housing 
sides,  which  are  blinking  alternately  1 s / 1 s  when  supply  voltage  is  available  at  the  +12V 
input. This function cannot be disabled. 
The  SP-4006  BL  siren  has  an  indicator  LED  situated  in  the  middle  of  the  lower  edge  of 
enclosure. The LED is blinking when supply voltage is present at the +12V input. Removal of 
the jumper designated as 

LED

 will disable the LED function. 

3.  Connection 

There  are  two  types  of  alarm  outputs  which  are  used  in  alarm  control  systems:  common 
ground  outputs  and  common  supply  outputs.  The  siren  can  be  activated  by  any  type  of 
output, provided that suitable connections are made. 

Note:

  The  converter  supplying  the  acoustic  siren  system  generates  a  very  high  voltage 

which  can  cause  electric  shock  when  touched.  Hence,  all  connections  may  only  be 
made when the battery is disconnected and the +12 V wire is to be connected last. 

 

INTEGRA 32

STO

TMP

SENS. TMP

TMP

STA

SP-4006

GND +12V

R

 

Fig. 2. Way of connecting the SP-4006 siren to the alarm control panel without a resistor in 

the siren tamper circuit. The OUT2 high-current output is programmed as the supply one. 

The OUT3 and OUT4 low-current outputs control the signaling (OUT3 will trigger the acoustic 

signaling, and OUT4 – optical). 

The Z1 zone is programmed as tamper, NC type.

 

 