R

 

 

Fig. 3. Connecting the SPL-2030 siren to high-current outputs of INTEGRA 32 

control panel. The OUT1 output will release optical signaling, and the OUT2 

output - acoustic (high-current outputs with normal polarization - activated when +12 V 

voltage is supplied). The Z1 zone is programmed as 24 h tamper. 

 
 
It is possible to control two types of signaling from one output of control panel, by connecting 
in parallel the terSA to +SO and -SA to -SO. 

Note: 

Some  control  panels  may  require  connecting  a  resistor  R  (approx. 1 kΩ) 

between 

the +SA- terminals in the siren

. If this resistor is not connected, the siren may emit 

some low sounds when not alarming. 

 
Description of the terminals: 

+SO- 

 – optical signaling terminals 

+SA- 

 – acoustic signaling terminals 

TMP

  – tamper circuit terminals 

Summary of Contents for SPL-2030-R

Page 1: ...of tamper protection sold separately including inner cover of galvanized metal sheet OM SPL2000 foam detector SPL SAB or SPL TO In order to install the SPL SAB detector remove the electronics board and unsolder the SMD component situated underneath the board designed for shorting the solder points J3 and J4 Next solder the detector leads to these points and using a screw attach the detector to the...

Page 2: ... 2030 device The tamper circuit of the siren will be open on removing the outer enclosure covering with mounting foam or detaching the siren from the wall For the tamper contact to function correctly during pull off the S element must be screwed to the mounting surface see Fig 1 Connectors TMP are designed for connecting into tamper circuit of security system By placing jumpers on the JP1 JP5 pins...

Page 3: ...activated when 12 V voltage is supplied The Z1 zone is programmed as 24 h tamper It is possible to control two types of signaling from one output of control panel by connecting in parallel the terminals SA to SO and SA to SO Note Some control panels may require connecting a resistor R approx 1 kΩ between the SA terminals in the siren If this resistor is not connected the siren may emit some low so...

Page 4: ...ow current outputs with normal polarization activated by shorting the terminal directly to the common ground 0 V The Z2 zone is programmed as 24 h tamper 4 Technical data Nominal power supply 12 V DC 20 Mean current consumption when signaling acoustic signaling 250 mA optical signaling 35 mA Working temperature range 35 60 C Sound pressure approx 120 dB Enclosure dimensions 298x197x90mm Weight 725...

Reviews: