Supply voltage ................................................................................................... 12 V DC ±15% 
Standby current consumption .......................................................................................... 10 µA 
Maximum current consumption ......................................................................................330 mA 
Sound pressure level (at 1 m distance)..................................................................up to 120 dB 
Backup battery .............................................................................................. battery 6LR61 9 V 
Standards complied with ......................................................................EN50130-4, EN50130-5 
Environmental class according to EN50130-5 .........................................................................II 
Operating temperature range.................................................................................. -10…+55°C 
Maximum humidity ..........................................................................................................93±3% 
Dimension

 x 40 mm 

eight............................................................................................................................... 162 g 

s ................................................................................................. 130 x 130

W
 

The declaration of conformity may be consulted at www.satel.eu/ce 

 
 

Always use the 6LR61 9 V batteries. The battery is not included with the siren 
and must be purchased separately. 

Service representative should periodically check the battery status within the 
scope of maintenance work. 

Be particularly careful when replacing the battery. If inappropriately done, 
replacement of the battery may lead to a risk of explosion. The Manufacturer 
bears no responsibility for any consequences of incorrect replacement of the 
battery. 

The used batteries must not be discarded, but should be disposed of in 
accordance with the existing rules for environment protection. 

 
 
 
 
 
 
 
 
 
 
 
 
 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gda

ń

sk • POLAND 

tel. + 48 58 320 94 00 

www.satel.eu 

 

Summary of Contents for SPW-150

Page 1: ... 1 Features Acoustic signaling by means of piezoelectric transducer Three selectable tones Tamper protection in 2 ways cover removing and tearing enclosure from the wall Battery back up power supply Alarm by main power failure Fig 1 The siren inside with cover removed Explanations for Fig 1 1 battery 2 mounting holes ...

Page 2: ...nsducer 6 pins for tone selection 7 description of setting jumpers for respective tone 3 Description of Operation The indoor siren requires power supply from a 12 V 15 DC voltage source The acoustic alarm will be triggered on loss of the control signal fed to the terminal D depending on the configuration common ground or 12 V DC voltage and continues until the signal is restored Additionally the s...

Page 3: ...after all installation work is completed and the alarm system power supply turned on If the battery is installed before the external power supply is turned on alarm will be triggered Fig 4 The way of connecting the siren to the alarm control panel OUTx control panel output with power supply function OUTy control panel output for signaling control Zx control panel zone programmed as 24h tamper Note...

Page 4: ...Always use the 6LR61 9 V batteries The battery is not included with the siren and must be purchased separately Service representative should periodically check the battery status within the scope of maintenance work Be particularly careful when replacing the battery If inappropriately done replacement of the battery may lead to a risk of explosion The Manufacturer bears no responsibility for any c...

Reviews: