background image

 

3.    Measuring Procedures 

(1)  Press the HOLD/

  key. After lit the whole area of the display, it is ready to measure the wind and 

temperature. 

(2)  Press the UNIT/MODE key and choose the Mode to measure.   

Each time the UNIT/MODE key is pressed, the measurement mode is switched in order of Wind 

Velocity Mode, Max Wind Velocity Mode, Temperature Mode and Wind Chill Mode as in following 

diagram. 

 
 
 
 
 
 
 
 
 

a)  Wind Velocity Mode 

Wind Velocity Mode is to measure the wind velocity. 

In  the  display  of  the  wind  velocity,  while  hold  the  HOLD/

  key,  press  the  UNIT/MODE  key, 

the unit set is cycled as follows.    Choose the unit displayed 

 
 
 
 
 

b)  Max Wind Velocity Mode 

Keep updating maximum value of wind velocity and displaying the value.   

The maximum value is reset as the device is turned off. 

c)  Temperature Mode 

Temperature Mode is to measure the temperature. 

While the device is in the Temperature Mode, each time the HOLD/

  key is pressed, unit of 

temperature measured switch between Celsius(°C) and Fahrenheit(ºF). 

d)  Wind Chill Mode 

Wind Chill Mode is to measure the Wind Chill. 

While  the  device  is  in  the  Wind  Chill  Mode,  each  time  both  HOLD/

  key  and  the 

UNIT/MODE  key  are  pressed  at  same  time,  unit  of  temperature  measured  switch  between 

Celsius(°C) and Fahrenheit(ºF). 

 

(3)  Direct  the  device  in  the way  that  the  wind measured  comes through  the  device  from  back (the 

side which serial number is printed) to front. 

(4)  Turn off the device by pressing the HOLD/

  key more than 3 seconds after use.

 

a) Wind Velocity Mode 

Wind Velocity Unit is displayed 

b) Max Wind Velocity Mode 

Max value is displayed 

d) Wind Chill Mode 

WCL is displayed 

c) Temperature Mode 

Temperature Unit is displayed 

Summary of Contents for PC-52D

Page 1: ...Instruction Manual No 7650 10 Mini Anemometer Model PC 52D 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english ...

Page 2: ... display and error may occur If the device is left in a car during summer time heat from sunlight may result in failure Do not leave it such a place Do not measure the wind speed by holding the device out of an automobile window while driving It is very dangerous Do not disassemble modify the device or use wrong battery Doing so result in inaccurate measurement or failure Do not drop the device or...

Page 3: ...ch as m s meter second ft min feet minute knot the wind chill factor and Beaufort wind scale can be displayed 1 Names and Functions of Components Main unit LCD display pane Display measured values and the operating status of the device ON OFF HOLD key Pressing this key turns the power on or off While the device is on pressing and holding the key holds freezes the readings UNIT MODE key Use to swit...

Page 4: ...lling or Replacing the Battery Replace the battery as follows before using the device for the first time or when low battery mark is displayed 1 Remove the battery lid by turning it counterclockwise direction of the arrow on the lid using a coin or the like 2 Take out the used battery in case of replacing a battery 3 Insert the new coin cell battery CR2032 facing upward the positive terminal 4 Rei...

Page 5: ...lue is reset as the device is turned off c Temperature Mode Temperature Mode is to measure the temperature While the device is in the Temperature Mode each time the HOLD key is pressed unit of temperature measured switch between Celsius C and Fahrenheit ºF d Wind Chill Mode Wind Chill Mode is to measure the Wind Chill While the device is in the Wind Chill Mode each time both HOLD key and the UNIT ...

Page 6: ...held 2 To release Hold function press the HOLD key again Light is turned off and the device is back to previous state 5 Auto power off function If the device is not operated for approximately 5 minutes the power is turned off automatically This function converses battery power even if you forgot to turn the power off How to release the auto power off function 1 While the device is power off keep p...

Page 7: ...ind velocity m s meter second 1 1 to 15 0m s Ft min feet minute 60 to 2952FTM knot 2 1 to 29 1KNT kilo meter hour 4 0 to 53 9KMH mile hour 2 5 to 33 5M H beaufort scale 1 to 7 Accuracy Temperature 1 C Wind velocity 1 1 m s 1 1 to 10 0m s 2 0m s others Resolution Temperature 0 1 C Wind velocity m s meter second 0 1 Ft min feet minute 1 knot 0 1 kilo meter hour 0 1 mile hour 0 1 beaufort scale 1 Sam...

Page 8: ......