background image

 

6. Error message

 

Measurement Target  Error Code  Cause 

Solution 

Wind velocity 

Hi  

Measured value exceeds 
measuring range 

Use the device within measurement 
range. If error message is still 
displayed, stop using it and contact 
the store from which the device was 
purchased or our service network 

Temperature 

Hi  

Measured value exceeds 
measuring range 

Lo  

Measured value is lower 
than measuring range 

Err  

Temperature sensor has 
something wrong 

Stop using the device and contact 
the store from which the device was 
purchased or our service network 

 

7. Specifications

 

Name 

Mini Anemometer 

Model 

PC-52D 

Catalog No.

 

7650-10 

Measurement range 

Temperature 

0.0 to 50.0°C 

Wind velocity 

m/s (meter/second) 

1.1 to 15.0m/s   

Ft/min (feet/minute) 

60 to 2952FTM   

knot   

2.1 to 29.1KNT 

kilo meter/hour 

4.0 to 53.9KMH 

mile/hour 

2.5 to 33.5M/H 

(beaufort scale) 

1 to 7 

Accuracy 

Temperature 

±

1°C 

Wind velocity 

±

1.1 m/s (1.1 to 10.0m/s) 

±

2.0m/s (others) 

Resolution 

Temperature 

0.1°C 

Wind velocity 

m/s (meter/second) 

0.1 

Ft/min (feet/minute) 

knot   

0.1 

kilo meter/hour 

0.1 

mile/hour 

0.1 

(beaufort scale) 

(1) 

Sampling time 

about 1 second 

Sensing elements 

Temperature: Thermistor     
Wind velocity: Vane (propeller) 

Ambient Temp. 

0 to 50°C (no condensation) 

Storage Temp. 

-10 to 50°C (no condensation) 

Power 

Lithium button battery (CR2032) x 1 

Battery life 

about 50 hours (continuous use) 

Materials 

Main unit : ABS resin 
Vane: ABS resin     

Dimensions 

Main unit:

 

44(W) x 130 (H) x 16(D) mm 

Weight 

about 54g (including a battery) 

Accessory 

Lithium coin cell battery (CR2032) x 1 
Manual x 1 
Hand strap x 1 

Summary of Contents for PC-52D

Page 1: ...Instruction Manual No 7650 10 Mini Anemometer Model PC 52D 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english ...

Page 2: ... display and error may occur If the device is left in a car during summer time heat from sunlight may result in failure Do not leave it such a place Do not measure the wind speed by holding the device out of an automobile window while driving It is very dangerous Do not disassemble modify the device or use wrong battery Doing so result in inaccurate measurement or failure Do not drop the device or...

Page 3: ...ch as m s meter second ft min feet minute knot the wind chill factor and Beaufort wind scale can be displayed 1 Names and Functions of Components Main unit LCD display pane Display measured values and the operating status of the device ON OFF HOLD key Pressing this key turns the power on or off While the device is on pressing and holding the key holds freezes the readings UNIT MODE key Use to swit...

Page 4: ...lling or Replacing the Battery Replace the battery as follows before using the device for the first time or when low battery mark is displayed 1 Remove the battery lid by turning it counterclockwise direction of the arrow on the lid using a coin or the like 2 Take out the used battery in case of replacing a battery 3 Insert the new coin cell battery CR2032 facing upward the positive terminal 4 Rei...

Page 5: ...lue is reset as the device is turned off c Temperature Mode Temperature Mode is to measure the temperature While the device is in the Temperature Mode each time the HOLD key is pressed unit of temperature measured switch between Celsius C and Fahrenheit ºF d Wind Chill Mode Wind Chill Mode is to measure the Wind Chill While the device is in the Wind Chill Mode each time both HOLD key and the UNIT ...

Page 6: ...held 2 To release Hold function press the HOLD key again Light is turned off and the device is back to previous state 5 Auto power off function If the device is not operated for approximately 5 minutes the power is turned off automatically This function converses battery power even if you forgot to turn the power off How to release the auto power off function 1 While the device is power off keep p...

Page 7: ...ind velocity m s meter second 1 1 to 15 0m s Ft min feet minute 60 to 2952FTM knot 2 1 to 29 1KNT kilo meter hour 4 0 to 53 9KMH mile hour 2 5 to 33 5M H beaufort scale 1 to 7 Accuracy Temperature 1 C Wind velocity 1 1 m s 1 1 to 10 0m s 2 0m s others Resolution Temperature 0 1 C Wind velocity m s meter second 0 1 Ft min feet minute 1 knot 0 1 kilo meter hour 0 1 mile hour 0 1 beaufort scale 1 Sam...

Page 8: ......

Reviews: