Table of Contents
Description
Page
Introduction
Overview
Features
1. Names and Functions of Components
……………………………… 1
2. Notes on Use
………………………………………………………… 4
3. Caution in storage
…………………………………………………… 5
4. Loading Batteries
… ………………………………………………… 6
5. Connecting the Sensor Probe
… …………………………………… 7
6. Connecting the Printer Terminal and the AC Adapter Jack
… …… 7
7. Operating Procedure
………………………………………………… 8
I General Temperature Measurement Methods
……………
11
I-1. Temperature Measurement Method
…………………………… 11
I-2. HOLD / REL Function
… ……………………………………… 11
I-3. MAX / MIN Function
… ………………………………………… 12
I-4. Alarm Setting of Upper and Lower Limits
… ………………… 13
I-5. °C / °F Switch Function ………………………………………
13
I-6. Auto Power-off Function ……………………………………
14
II Methods for Measuring Temperature in Storage Mode
……
15
II-1. Setting Modes
… ……………………………………………… 15
II-2. Setting Time
…………………………………………………… 15
II-3. Setting the Recording Interval
………………………………… 16
II-4. Setting Management Numbers
… …………………………… 17
II-5. Manual Storage Mode
… ……………………………………… 17
II-6. Auto Storage Mode
… ………………………………………… 18
III Printing Stored Data
……………………………………………
20
III-1. Connecting the Main Unit and the Printer
……………………
20
III-2. Printing Stored Data
… ………………………………………
20
III-3. Examples of the Printed Data
…………………………………
21
IV Error Message
… ……………………………………………
22
V
Specifications
…………………………………………………
23
VI Warranty Policy
………………………………………………
24
Warning
The SK-1260 is not explosion-proof. Never use it in an atmosphere
containing flammable gases.
…
Beware of explosion!
There is a risk of explosion. Take extreme care.
**
If you have any questions, contact the dealer from which the unit
was purchased, or our service network.
Features
・
Waterproof Function
The main unit connected with probe has a waterproof structure that
conforms to IPX 4 (waterproof level 4 : splash-proof type) in JIS C
0920. Even if the main unit is touched with wet hands or is subject
to splashes of water, its functions will not be affected.
・
Choice of 2 methods in storage
Measured data can be stored in the main unit manually or
automatically by the settings. The stored data are output to an
optional printer.
For details, see "In Storage Mode".
・
MAX / MIN Alarm Setting
Upper and lower limits can be set. If the temperature reaches the
upper or lower limit, the alarm buzzer sounds to alert.
・
Compatibility in the main unit and probes
The main unit is fully compatible with both a thermistor sensor
probe and a thermocouple (K) sensor probe.
Summary of Contents for SK-1260
Page 16: ......