47
LED Indicators:
Power and Ready LEDs blink alternately
Power LED
Ready LED
ON
OFF
OFF
ON
Possible Problems
Solutions
Remarks
Ribbon out
Supply the ribbon roll
Not applicable to
direct thermal
type.
Ribbon jam
Recover the jam
Ribbon sensor error Replace ribbon sensor
LED Indicators:
Only the Power LED blinks
Power LED Ready LED
ON
OFF
ON
OFF
Possible Problems
Solutions
Remarks
Serial IO error
Check the baud rate
Serial interface only
Memory full
Add the extension RAM (flash
memory card)