Codabar
Command Structure
1:3 ratio
<ESC>B0bbcccd (data) d
2:5 ratio
<
ESC>BD0bbcccd (data) d
1:2 ratio
<ESC>D0bbcccd (data) d
bb
=
Width of narrow element in dots (01-12)
ccc
=
Bar height in dots (001-600)
d
=
Required Start and Stop character (A, B, C, or D)
(data) =
Bar code data (alphanumeric)
Character Set
0-9, -,$,:,/,+
A, B, C, D (Start/Stop characters)
Density Table
Printer
Model
Narrow/
Wide
Ratio
Value
of “bb”
“X”
Dimension
(mils)
Density
(char/inch)
M-8400RVe
1:3
01
5.0
16.9
1:3
02
10.0
8.5
2:5
01
10.0
9.2
1:2
02
5.0
10.2
Example
<ESC>H0400<ESC>V0025<ESC>B002100A12345B
<ESC>H0440<ESC>V0135<ESC>XS12345
Notes
You must add the appropriate (A, B, C or D) Start and Stop characters
to the data string. The printer does not automatically add them when
printing.
Page B-2
PN 900107
5A
SATO M8400RVe
Appendix B: Bar Code Specifications