Stop Bit Selection (DSW1-4). Selects the number of stop bits to end each byte
transmission.
Baud Rate Selection (DSW1-5, DSW1-6). Selects the data rate (bps) for the
RS232 port.
Protocol Selection (DSW1-7, DSW1-8). Selects the flow control and status
reporting protocols. See
Section 6: Interface Specifications
for more information.
(* Will select protocol for M-8400 if DSW2-8 is ON)
Printer Set Up
Print Mode Selection (DSW2-1). Selects between direct thermal printing on
thermally sensitive paper and thermal transfer printing using a ribbon.
Sensor Type Selection (DSW2-2). Selects between the use of a label gap or a
reflective Eye-Mark detector.
Page 3-2
PN 900107
5A
SATO M8400RVe
Section 3: Configuration
DSW1-5
DSW1-6
SETTING
Off
Off
9600
Off
On
19200
On
Off
38400
On
On
57600
1
2
3
4
5
6
7
8
ON
OFF
DSW1
DSW1-7
DSW1-8
SETTING
Off
Off
Rdy/Bsy
Off
On
Xon/Xoff
On
Off
Bi-Com 3
On
On
Bi-Com 4*
1
2
3
4
5
6
7
8
ON
OFF
DSW1
DSW1-4
SETTING
Off
1 Stop Bit
On
2 Stop Bits
1
2
3
4
5
6
7
8
ON
OFF
DSW1
DSW2-1
SETTING
Off
Therm Xfr
On
Direct Therm
1
2
3
4
5
6
7
8
ON
OFF
DSW2
DSW2-2
SETTING
Off
Gap
On
Eye-Mark
1
2
3
4
5
6
7
8
ON
OFF
DSW2