External Signal Type Selection (DSW3-6, DSW3-7). Both the polarity and
signal type (level or pulse) of the external print synchronizing signal can be selected.
See
Section 6: Interface Specifications
for a definition of signal types.
Repeat Print via External Signal (DSW3-8). Allows the applicator to reprint
the last label of the print job. See
Section 6: Interface Specifications
for a description of
the signal requirements.
M8400RVe
PN 900107
5A
Page 3-5
Section 3: Configuration
DSW3-6
DSW3-7
SETTING
Off
Off
Type 4
Off
On
Type 3
On
Off
Type 2
On
On
Type 1
1
2
3
4
5
6
7
8
ON
OFF
DSW3
DSW3-8
SETTING
Off
Disabled
On
Enabled
1
2
3
4
5
6
7
8
ON
OFF
DSW3