background image

 

Installation Operation Maintenance 

 

ESCB-

48

  – 

48

"  MEDIUM  DUTY  CHARBROILER

 

 

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE 

 

SATURN EQUIPMENT 

OWNER’S MANUAL 

Gas Charbroiler – Medium Duty 

Gas equipment manufactured for Saturn Equipment are for use with the type of gas specified on the rating plate  

and for installation will be in accordance with National Fuel Gas Code ANSI Z223.1 (latest edition) 

FOR YOUR SAFETY

  

Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

 

Instructions to be followed in the event the user smells gas fumes must be posted in a prominent location in the  

installed kitchen area. The information shall be obtained from a local gas supplier. 

WARNING:

 Improper installation, adjustment, alteration, service and maintenance can cause property damage,  

injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or  

servicing this equipment.

 

 

SATURN EQUIPMENT 

www.saturnequipment.com

 

Summary of Contents for ESCB-48

Page 1: ...R SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Instructions to be followed in the event the user smells gas fumes must be posted in a prominent location in the installed kitchen area The information shall be obtained from a local gas supplier WARNING Improper installation adjustment alteration service and maintenance can ca...

Page 2: ...ons design and material Possession of this price list does not constitute an agree ment or offer to sell product to the possessor Prices are subject to change without notice Prices do not include sales tax All prices are in U S dollars Returned goods are subject to a 20 restocking charge and the cost of reconditioning the equipment for resale Prior to returning the goods a Return Goods Autho rizat...

Page 3: ...tain the container for inspection Manufacture cannot assume liability for damage or loss incurred in transit We will however at your request supply you with the necessary documents to support your claim TABLE OF CONTENTS WARRANTY Page 1 SPECIFICATIONS Page 2 FEATURES OPERATING CONTROLS Page 3 PRECAUTIONS GENERAL INFORMATION Page 4 AGENCY LISTING INFORMATION Page 4 INSTALLATION Pages 5 6 7 8 OPERAT...

Page 4: ...FEATURES OPERATING CONTROLS DRIP PAN TRAY BURNER OFF BURNER ON BURNERS GRATE GAS MANIFOLD INTERIOR COMPONENTS PILOT LIGHT CONTROL VALVE RADIANT PILOT BURNER ADJUST FEATURES AND OPERATING CONTROLS ...

Page 5: ...bmerge appliance or burners in water This appliance is not jet stream approved DO NOT direct water jet or steam jet at this appliance or at any control DO NOT splash or pour water on in or over any controls DO NOT wash counter around this appliance with water jet Burners which have become wet must be thoroughly dried before use Burner and grate surfaces will be very hot when in use Contact will ca...

Page 6: ...lationInstruction Sheet packed with the appliance before starting anyinstallation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for later use COMPONENTS Adjustable Legs set of 4 Drip Tray SETUP This appliance is designed for use in non combust...

Page 7: ...the gas burners Additionally 1 The gas supply line used to connect the charbroiler to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be inside 3 4 diameter or greater 3 Use pipe sealant made specifically for gas piping on all pipe joints Apply sealant sparingly to the male threads only Sealant must be resistant...

Page 8: ...sure which must match the nameplate specifications Connecting the charbroiler to the wrong fuel type and or pressure will compromise the safety and or performance of the appliance BE SURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE SURFACES The charbroiler must be placed in its final operational position and leveled front to back and side to side with a spirit level prior to beginning the gas p...

Page 9: ...he rear pilot Using a small flat blade screwdriver turn the screw clockwise to decrease the flame size or counter clockwise to increase the flame size Adjust the pilot flame to 1 4 high Test for operation inside and outside sections of the burner must light without undue delay Drafty conditions may require a higher flame to allow the pilot to remain lit ADJUST BURNER FLAME Remove all burner contro...

Page 10: ... knob will not turn by hand DO NOT attempt to force or repair it Contact your manfacturer for repairs Forced or improperly repaired valves pose the risk of fire and or explosion Make sure burners pilot burner and drip tray are properly installed before attempting to operate LIGHTING THE PILOT FLAME Before lighting the pilot light smell all around the appliance area for gas Be sure to smell near fl...

Page 11: ...urner by turning the control knob to the ON position until fire forms completely around the inner and outer sections of the burner Set the control knob to the desired position The setting can be readjusted at any time WARNING FIRE HAZARD NEVER attempt to force or repair a stuck control valve Contact your manufacturer for repairs Forced or improperly repaired valves pose the risk of fire and or exp...

Page 12: ...etely before cleaning FREQUENCY Daily TOOLS Steel Brush with scraper Plastic Scouring Pad Soft Bristled Fiber Brush Mild Detergent Non Abrasive Cleanser Clean Soft Cloth Sponge CLEANING CHARBROILER 1 Remove the grates from the charbroiler Clean grates a Use the steel brush with scraper to remove food particles and residue from grate surfaces b Grate may be washed in sink or dishwasher c Dry the gr...

Page 13: ... in cabinet Remove radiants and main burners Examine burner assemblies Note position of air shutters before cleaning Clean food particles from burners with warm water mild detergent and a bristle brush If necessary reflectors may be removed from burners for cleaning by removing the retaining wire Cleaned with a plastic scouring pad and mild detergent Dry thoroughly before reinstalling on burners R...

Page 14: ...er Remove burner and dry thoroughly Damaged temperature control Burner or other internal component Contact manufacturer for repairs Pilot will not light Gas supply off Check main unit gas valves Air in lines Turn pilot valve on Attempt to light pilot every 15 sec Pilot valve not on Turn pilot valve on adjust Burner not hot enough Temperature control not set Adjust for desired temperature Shutter o...

Page 15: ...VICE DATA please have this information available if calling for service RESTAURANT______________________________ LOCATION _______________ INSTALLATION DATE _________________________ TECHNICIAN______________ SERVICE COMPANY __________________________________________________ ADDRESS STATE ZIP TELEPHONE NUMBER _____ EQUIPMENT MODEL NO _____________________________________ EQUIPMENT SERIAL NO ________...

Page 16: ...Page 15 ...

Page 17: ...Page 16 ...

Reviews: