5. ELECTRONIC CONTROLLER INSTRUCTION
5-1-1.
DIXELL XR20C PARAMETER FOR REFRIGERATOR
NO.1
SMG12
NO.
Label
Name
Range
Hidde
n
Par.
Defau
lt
℃
/
℉
℃
℉
1
Set
Set point
LS-US
-5/23
0
32
2
Hy
Differential
0.1-25.5
℃
/1-
255
℉
2/35.6
2.5
5
3
Ls
Minimum set point
-50
℃
-SET/-
58
℉
-SET
Yes
-50/-
58
-2
28
4
Us
Maximum set point
SET-
110
℃
/SET-
230
℉
Yes
110/23
0
10
50
5
Ot
Thermostat
probe
calibration
-12-12
℃
/-120-
120
℉
0/32
1
-1
6
P2P
Evaporator
probe
presence
n=not
pres. ;y=pres
.
Y
Y
Y
7
OE
Evaporator
probe
calibration
-12-12
℃
/-120-
120
℉
Yes
0/32
0
0
8
Ods
Outputs delay at start up
0-255min
Yes
0
2
2
9
AC
Anti-short cycle delay
0-50min
1
2
2
10
CCt
Continuous
cycle
duration
0.0-24.0h
Yes
0.0
0.0
0.0
11
COn
Compressor ON time with
faulty probe
0-255min
Yes
15
10
10
12
COF
Compressor
OFF
time
with faulty probe
0-255min
Yes
30
10
10
13
CF
Temperature
measurement unit
℃
/
℉
Yes
℃
/
℉
℃
℉
14
rES
Resolution
in=integer;
dE
=
dec .point
DE
DE
DE
15
Lod
Probe displayed
P1;P2
Yes
P1
P1
P1
16
EdF
Defrost
termination
setting
Pb=by
temper.;nP=b
y time
Pb
Pb
Pb
17
dtE
Defrost
termination
temperature
-50-50
℃
/-58-
122
℉
8/46.4
7
41
18
IdF
Interval between defrost 1-120ore
6
6
6
Summary of Contents for SMG12
Page 3: ...1 FEATURE CHART 1 1 OUTSIDE DRAWING OF SMG12 2 WIRING DIAGRAM 2 1 SMG12...
Page 4: ...3 PARTS DETAILS 3 1 FRONT PANEL THERMOSTAT MAIN SWITCH...
Page 6: ...DRAIN PAN CONDENSER FAN MOTOR ASSEMBLY FAN COVER CONDENSER FAN MOTOR BLADE CONDENSER FAN MOTOR...
Page 7: ...3 3 DOOR GASKET Magnetic gasket can be replaced without any tools...
Page 9: ...Evaporator Defrost Heating Element Evaporator Fan Fan Support...
Page 19: ...B TAKE OFF THE ELEMENT AND CHANGE IT 6 3 CONDENSING UNIT 6 3 1 TAKE OFF THE BOTTOM PANEL...