16
brilliance
jubilee
Safety feature on:
the red indicator is
visible from the cap
centre and in the
upward position.
Safety feature off:
the red button is
in the downward
position.
Firmly push on the
rubber cap to push
down the red
button.
1
3
2
The filler cap should not be opened when the unit is still under pressure. If
the red indicator on the filler cap is in the upward position this means that the
unit is still under pressure.
Never press the red indicator on the filler cap downwards with an object and
turn the cap at the same time.
When there is no more pressure in the tank, the red indicator will be in the
downward position and the cap can be opened. In case of doubt, contact
Sauber Customer Service.
1. Ensure the tank is empty and there is no steam in the boiler. Turn off the machine
and let it cool down completely, this can take up to a few hours.
2. After the unit has cooled down completely, firmly push down on the filler cap until
the red indicator in the centre of the cap is in the downward position. This will
unlock the cap allowing you to unscrew and remove the cap from the machine.
3. Carefully turn the cap anti-clockwise to remove it from the machine. If steam
releases, do not unscrew the cap any further, allow the machine to cool down then
repeat the above steps.
Filler cap