Planning, transport, installation
LASERTEC 40
Page 13
Ambient conditions for the machine
•
Permissible ambient temperature: +15° to + 35° C
•
Maximum installation height: 1000 m above sea level
Max. relative humidity
When the ambient temperature is +15°C, the max. relative humidity must
not exceed 95 %; when the temperature is +35°C, it must not exceed 30
%. Otherwise condensation can form on the end of the laser crystal.
Limit values for the relative humidity referred to the ambient temperature.
If one of these figures is exceeded at the place the machine is installed, or
in case of special operating conditions, e.g.
•
action of powerful electric or magnetic fields
•
installation in potentially explosive atmospheres or areas containing
potentially explosive substances
consult SAUER GmbH.
Information for machines with series transformer
The cable connection between the overcurrent protection device (main
fuse) and the separate series transformer depends on the operating
voltage at the customer. Appropriate protection against short circuits is to
be provided by the customer.
The cable for the connection between the series transformer and the
machine is not included with the items we supply (to suit the installation
location in the installation diagram).
Empty conduits for external data transfer
If external data transfer is planned, appropriate empty conduits
made of
metal
must be installed for the data cable.
Data cables must not be laid alongside cables carrying high currents
or cross such cables.