Installation instruction of controller
!
Important:
Before installing the controller, make sure the steam
generator
is shut off
otherwise the controller may be damaged.
Step one
Determine the installation location of the controller.
The controller is designed to be installed in the steam
room :
1.
4-5 feet from the ground.
2.
A
way from the steam nozzle and do not expose
under the direct
path
of steam.
3.
Instal
lation on
perpendicular wall.
4.
The position of installation should facilitate easy
operation and convenient wiring
.
The controller wire is 1.
0
feet long with a controller
lengthened wire of 20 feet long at the most. In the
installation of controller, it should be in a position not
more than 21 feet from the steam engine. If longer
wire is needed, contact professional service personnel.
!
Important:
18
User Manual
!
Important:
Do not
install the
controller under
the
water pipe or in a position where
water comes
into contact.
Step two
Drill a round hole of 35mm in diameter in a chosen
position, no larger or smaller.
Step
three
Pull
the
controller
wire
through
the
round
hole,
connect it to the lengthened wire and then to the steam
generator
,
and connect with the corresponding wire in
the
generator
.
When the computer wire is plugged in, aim
at
the direction and insert horizontally, instead of shaking
left and right in case the computer needles
could be
damaged. Do
the same
when unplugging.
!
Do not
pull tight, or clip tight the
controller wire
in case
of causing damage to it.
Step four
Start the power supply of steam engine, check and
adjust connection, check each item on the page to
make sure all functions work well.
before
repairing the controller, make
sure
the
steam
generator
is
shut
off
otherwise
the
controller may
be
damaged.
Important:
A
or
Control Panel
(1ft)
(1ft)
(20ft)
SS II
Extended wire
Steam Generator
Control Panel
SS I
Summary of Contents for KWS 10.5
Page 25: ...s ight s Page 25...