Fig 2
Fig.3
Fig.4
Fig.5
When the actual temperature is smaller than or equal to 32
, the
digital tube will display 32
. When the actual temperature is
smaller than or equal
, the digital tube will display
. The last digit displays as the unit of Fahrenheit
temperature. The default start time of steam function is 30
minutes. When the steam is starting, there is a shortage of water,
the heating wire will stop heating and the water input valve will
start automatically. If there is no water tested in 5 seconds or no
water coming to reach the full volume in 15 seconds, the digital
tube will flash to display (as shown in Fig.3) to hint mistake.
If the water is full, the steam function will return to normal.
When the steam function is started, if the temperature of the
environment is higher than the set steam temperature, the
heating wire will stop heating, the digital tube will flash to
d i s p l a y t h e c u r r e n t e n v i r o n m e n t t e m p e r a t u r e ; w h e n t h e
e n v i r o n m e n t t e m p e r a t u r e i s l o w e r t h a n t h e s e t s t e a m
temperature, the heating wire will restore heating, the digital
tube will display normally current environment temperature.
When the system is started, press button or when the
steam function time is due, the system will be shut. 10 minutes
after the system is shut off, the drainage function will be started
automatically for 5 minutes.
Time setting
When the machine is started, press button and the digital tube
will display the remaining time of current steam function (as
shown in Fig.4), press button or button to adjust the
remaining time. The adjustment range is 5-60 minutes with
minute as one level. If there is no adjustment in 5 seconds, the
system will quit the time setting function. The digital tube will
restore to display current environment temperature.
Temperature setting
Whenthemachine is started,press
button and the digital tube
will display the set steam time (as shown in Fig.5), at the same
time the temperature unit will flash to hint that the machine has
entered the steam temperature setting function. At this time, press
button or
button to adjust the temperature parameter.
The adjustment range is 50-1 0
with 1
as one level. If there is
no adjustment in 5 seconds, the system will quit the temperature
setting function. The digital tube will restore to display current
environment temperature.
Page 21
User Manual
Do NOT set temperature setting more than 110F (45C)
to 110 F
110 F
F
F
Summary of Contents for Xtreme Steam Tech Steamcore Spa II
Page 30: ... s ight s Page 28 ...
Page 31: ... ...