Common
trouble shooting methods
To facilitate your use and maintenance of sauna room, the following common
trouble shooting methods are listed for
refere
n
ce
.
Troubles
Causes of troubles
Trouble-shooting methods
The machine
does not start
when
electrified
1.The fuse is burned.
2.The wire connection terminal
becomes loose.
3.Not good contact in the
connection wire between the
controller and the steam engine.
1.Change the fuse (on the shell 0.8A/
250V)
2.Plug tight the wire connection terminal
3.Make sure the steam engine and the
controller come into good contact
Electricity
leakage switch
breaks
automatically
1.The wire connector is dampened
or damaged.
2.The heating tube breaks
1.Check whether the wire connector is
dampened or damaged, and dry with
dryer if dampened.
2.
Change a heating tube.
When the machine is
started, hot water
comes out with little
or no steam
1. The water drainage valve is broken.
1. Change a water drainage valve.
The display screen
on the control panel
does not display
1.The power wire is not connected well
or not in good contact. The connection
plug between the control panel and the
electrically-controlled box becomes
loose.
2.Trouble with plugboard.
1.Check whether the connection plug between
the control panel and the electrically-
controlled box has become loose, and
whether the power circuitry has good contact.
2.Change a plugboard.
Water leakage
1.The water pipe connector becomes
loose or the pipe breaks
2.Water leakage in the water input
valve or the waterdrainage valve
1.Tighten the loose connector, and change the
broken pipe.
2.Change the water input valve or the water
drainage valve.
No steam when
starting the
machine
1.No electricity.
2.No water.
3.The set temperature is too low
4.Troublewithwire.
1.Check the power supply
2.Check the water input pipe and water input
valve
3.Reset the temperature
4.Contact the distributor
The steam does not
come out, the water
sounds in the
machine
1. The steam pipe is jammed.
1. Cut power supply to check whether the
steam pipe is smooth.
The light can not
be turned on
1. The fuse is burned.
2. The light is broken
3. The wire is broken
4. The plug does not have good contact
1.Change the fuse (on the shell 1A/250V)
2. Change a light bulb.
3. Change wire.
4. Make the contact good.
The display box
displays normally
with no steam
input
1.Too much pressure inside the steam
engine, so the system breaks for heat
protection.
2.Wire is broken for heat protection.
1.Check the steam transport pipe and restore
automatically after heat protection
becomes cool.
2.Check the heat protection wire to make sure
the connection is good.