Important:
1.Please consult your distributors of building materials like acryl
ic
, fiber glass or other
anti-heat sheet about the installation position of steam nozzle. It is suggested that MS-
103412 anti-heat material can be used.
2.In the entire steam room, it is required that steam
must
not leak out. The pipes, its
accessories and the holes in the wall should be airproof by applying
silicone
so
that no steam will enter the holes in the wall.
If non-heat-resistant material like
acryl
ics
is used as building material,
reserve a gap no less
than 1/4''
and fill with
silcone
.
Silicone
Use
s i l i c o n e t o f i l l i n t h e
g a p s i n t h e w a l l t o
a
chieve the water proof and
damp-proof effect.
Inside wall
of
the steam room
Drainpipe (1/2'')
According to national or local
codes
, the steam
generator
drainage valve should be equipped
with
a
drain
pipe. The steam
generator
drains the water by using
gravity
.
The drain
pipe should not incline upwards so as to
prevent
the drainage of water.
Safety Pressure valve(s)
1.
Pressure valve is a safe
ty
equipment in order to prevent too much steam pressure in
the steam
generator
due to various reasons; such as, steam line blockage,
2.
The Steam Safety Pressure Valve & Switch Application is Mandatory.
Attention:
Page 4
User Manual
(Supplied only - must be installed on-site by plumber)
A Pressure Safety Valve (Steam Pressure Valve) has been supplied with this steam generator unit.
The steam generator has removable sealed plugs in place of the pressure valve mounting location (labelled).
Unscrew the plugs, and screw on the pressure relief safety valve supplied. Make sure hi-heat silicone
is used to seal the safety valves to the boiler tank when attaching, allow silicone to cure 24 hours.
The Pressure safety relief valve must be installed by a qualified licensed experienced plumber.
undersized steam lines, steam line traps, vandalism, etc.
A qualified licensed plumber must install the supplied pressure valve during installation of the steam generator.
Steam Generators 18 KW (18000 watts) and higher will have a factory installed Steam Pressure Switch.
This switch will cut power to the steam generator when the inside of the boiler tank or steam line(s)
pressure reaches over the manufacture's recommended limit. The switch will reset and activate power
when the excessive pressure has been substantially reduced. This will re-occure until the cause of excessive
pressure has been rectified.
DO N OT H EAT AU T O FI LL / DRAI N V ALV ES WI T H T ORCH DU RI N G I N ST ALLAT I ON .
This will cause damage to the plastic solenoid valve which will cause malfuction or leakage.
DO NOT REDUCE THE STEAM LINE PIPE DIAMETER.
Steam generators 10.5 kw and up have an additional manual drain port
right next to the auto drain port. This is only used for manual draining and
should remain closed at all times.
Aroma Essence Reservoir
(apply a few drops)