background image

0020096286

 GAS VALVE 

(HONEYWELL)

MODEL

 

Ecosy SB 28E

Ecosy 28E

KIT Pt. No. 05632900

incl.

1 off “O” ring

4 off screws

MODEL

 

Ecosy 24E

Ecosy SB 24E

KIT Pt. No. 05617100

IMPORTANT NOTE

THESE INSTRUCTIONS SUPERCEDE

THE GAS VALVE SETTING PROCEDURE CONTAINED

WITHIN THE ORIGINAL APPLIANCE LITERATURE.

Summary of Contents for Ecosy 2 SB 28E

Page 1: ...y SB 28E Ecosy 28E KIT Pt No 05632900 incl 1 off O ring 4 off screws MODEL Ecosy 24E Ecosy SB 24E KIT Pt No 05617100 IMPORTANT NOTE THESE INSTRUCTIONS SUPERCEDE THE GAS VALVE SETTING PROCEDURE CONTAINED WITHIN THE ORIGINAL APPLIANCE LITERATURE ...

Page 2: ...he appliance combustion circuit and relevant seals Electrical gas and water connections System pressure the combustion performance operational gas inlet pressure and gas rates refer to the following procedure ALL MODELS Refer to the installation and servicing instructions supplied with your boiler to fit the replacement gas valve After assembly test for gas soundness and purge in accordance with t...

Page 3: ...standard NOTE Due to the modulating operation of the boiler and the need to check the gas inlet pressure and measure the gas rate at maximum rate it will be necessary to force it to maximum Operational Gas Inlet Pressure With ALL other gas appliances operating check the operational supply pressure at the gas service isolation valve test point refer to your Installation literature supplied with you...

Page 4: ...MUM Ecosy SB 24E 9 0 9 4 CO2 9 2 9 6 CO2 0 004 2 6 m3 h Ecosy 24E 9 0 9 4 CO2 9 2 9 6 CO2 0 004 2 6 m3 h Models SETTING OUTPUT SETTING OUTPUT MAX Nat Gas G30 Case Off Nat Gas G30 Case On CO CO2 OUTPUT MIN 9 9 kW MAX 20 4kW MIN 9 9 kW MAX 20 4kW Ratio Ecosy SB 24E 10 0 10 3 CO2 10 3 10 6 CO2 0 004 Ecosy 24E 10 0 10 3 CO2 10 3 10 6 CO2 0 004 Models SETTING OUTPUT SETTING OUTPUT MAX Nat Gas G31 Case ...