7
2000225294A
User Instructions - Appliance Introduction
The
EnviroPlus F24e & F28e
boilers are wall mounted high
efficiency condensing combination boilers with electronic ignition
providing central heating and instantaneous hot water.
The
EnviroPlus F28e SB
boiler is a wall mounted high
efficiency condensing system boiler with electronic ignition
providing central heating and indirect hot water.
Both the central heating and domestic hot water (F24e & F28e
only) temperature are user adjustable.
F24e & F28e ONLY
Domestic hot water demand always has
priority over heating demand.
The boiler is designed for use as part of a sealed water central
heating system with fully pumped circulation. The pump,
expansion vessel and associated safety devices are all fitted
within the boiler.
The boilers have fan assisted balanced flues which both
discharges the products of combustion to and draws the
combustion air from the outside of the room.
The boilers are suitable for horizontal top, vertical flue or
twin-pipe flue system connection. Refer to section 8 of these
instructions and the Saunier Duval flue options guide
(available from your nearest stockist) for further information.
Manufacturer's instructions must not be taken as overriding
statutory requirements. Reference in these instructions to British
standards and statutory regulations/requirements apply only to
the United Kingdom. For Ireland the current edition of I.S.813
"Domestic Gas Installations" must be used.
These instructions should be carefully followed for the safe and
economical use of your boiler.
Note:
The boiler serial number is marked on the data label
attached to the inner casing panel. The 'Controls & lighting'
section describes how to safely use the boiler.
User Instructions - Appliance Safety Devices
Accessories
A range of accessories are available.
For further information contact your supplier.
Overheating safety
In the event of the boiler overheating the safety devices will
cause a safety shutdown. If this happens, call your installation/
servicing company.
Electrical supply failure
The boiler will not operate without an electrical supply. Normal
operation of the boiler should resume when the electrical supply
is restored.
Reset any central heating system controls, to resume normal
operation.
If the boiler does not resume normal operation turn the mains
reset switch off and on. If the boiler does not resume normal
operation call your installation/servicing company.
Heating safety valve
CAUTION:
A Safety Valve with a discharge pipe is fitted to this
boiler.
The valve
MUST NOT BE TOUCHED
except by a
competent
person
. If the valve discharges at any time, switch the boiler off
and isolate it from the electrical supply. Contact your installation/
service company.
Frost protection
The appliance
has a built in frost protection device that protects
the boiler from freezing. With the gas and electric supplies ON
and irrespective of any room thermostat setting, the frost
protection device will operate the pump when the temperature
of the boiler water falls below 7
O
C.
The burner will fire if the temperature inside the boiler falls to
3
O
C.
When the temperature reaches 10
O
C the boiler stops.
Any other exposed areas of the system should be protected by
a separate frost thermostat.
Summary of Contents for EnviroPlus F24e
Page 18: ...18 2000225294A Diagram 5 1 11907 5 Boiler Schematic F24e F28e ONLY ...
Page 19: ...19 2000225294A 5 Boiler Schematic Diagram 5 1a 12248 BYPASS F28e SB ONLY ...
Page 49: ...49 2000225294A 14 Fault Finding 12410 Diagram 14 4 ...
Page 51: ...51 2000225294A 15 Wiring Diagram Diagram 15 1a 12240 F28e SB ONLY ...