1 Important
information
WARNINGS
Gas Leak or Fault
Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e. smoking, blowlamps, hot air
guns, etc. Do not operate electrical lights or switches either on or off. Open all doors and windows, ventilate the area.
Sheet Metal Parts
This boiler contains metal parts (components) and care should be taken when handling and cleaning, with particular
regard to edges.
Sealed Components
Under no circumstances must the User interfere with or adjust sealed parts.
Gas Category
This boiler is for use only on G20 natural gas, but the 30cxi may be
converted for use on G31 gas (Propane L.P.G.).
Gas Safety (Installation and Use) Regulations
In your own interests and that of safety, it is the Law that ALL gas
appliances are installed by a competent person in accordance with
the current issue of the above regulations.
Testing and Certifi cation
This boiler is tested and certifi cated for safety and performance.
It is, therefore, important that no alteration is made to the boiler,
without permission, in writing, by Saunier Duval.
Any alteration not approved by Saunier Duval, could invalidate the
certifi cation, boiler warranty and may also infringe the current issue
of the statutory requirements.
CE Mark
This boiler meets the requirements of Statutory Instrument, No.
3083 The Boiler (Effi ciency) Regulations, and therefore is deemed
to meet the requirements of Directive 92/42/EEC on the effi ciency
requirements for new hot water boilers fi red with liquid or gaseous
fuels.
Type test for purposes of Regulation 5 certifi ed by: Notifi ed body
0087.
Product/production certifi ed by: Notifi ed body 0086.
The CE mark on this appliance shows compliance with:
1. Directive 90/396/EEC on the approximation of the laws of the
Member States relating to appliances burning gaseous fuels.
2. Directive 73/23/EEC on the harmonisation of the Laws of the
Member States relating to electrical equipment designed for use
within certain voltage limits.
3. Directive 89/336/EEC on the approximation of the Laws of the
Member States relating to electromagnetic compatibility.
Control of Substances Hazardous to Health
Under Section 6 of The Health and Safety at Work Act 1974, we are
required to provide information on substances hazardous to health.
The adhesives and sealants used in this appliance are cured and
give no known hazard in this state.
Insulation Pads / Ceramic Fibre
These can cause irritation to skin, eyes and the respiratory tract.
If you have a history of skin complaint you may be susceptible to
irritation. High dust levels are usual only if the material is broken.
Normal handling should not cause discomfort, but follow normal
good hygiene and wash your hands before eating, drinking or going
to the lavatory.
If you do suffer irritation to the eyes or severe irritation to the skin
seek medical attention.
Electrical Supply
The boiler must be earthed.
All system components shall be of an approved type and all wiring
to current I.E.E. wiring regulations.
External wiring must be correctly earthed, polarised and in accor-
dance with the relevant standards.
In GB this is BS 6891.
In IE this is the current edition of I.S.813 “Domestic Gas Installa-
tions”.
The boiler must be connected to a permanent 230V ac, 50Hz sup-
ply.
Connection of the whole electrical system of the boiler, including
any heating controls, to the electrical supply must be through one
common isolator and must be fused 3 Amp maximum.
Isolation should be by a double pole switched fused spur box, with
a minimum gap of 3mm for both poles. The fused spur box should
be readily accessible and preferably adjacent to the appliance. It
should be identifi ed as to its use.
Alternatively connection can be made through an unswitched shut-
tered socket and 3A fused 3-pin plug both to the current issue of BS
1363 may be used, provided they are not used in a room containing
a bath or shower.
Wiring to the boiler must be PVC 85°C insulated cable, not less than
0.75mm2 (24/0.20mm).