24
25
TECHNICAL
DATA
CONTROL PANEL:
• Temperature adjustment range
40–90 °C.
• Pre-setting the schedule for the
week.
• Allows you to set the operating
time of the heater: up to 6 hours in
a private sauna, up to 12 hours in a
public sauna.
• For longer operating times, consult
the importer/manufacturer.
• Climate device three-speed con-
trol.
• Dimensions: 104 mm × 83 mm ×
19.3 mm
POWER UNIT:
• Supply voltage: 240V 3N~.
• Heater power rating up to 12 kW.
• Heaters with higher power need a
separate “contactor box.”
• Dimensions: 61 mm × 160 mm ×
225 mm.
• Safety device: door sensor, over-
heat protector.
Storage conditions: -30–80 °C.
TECHNIC
AL
D
ATA
TECHNIC
AL
D
ATA
1.
2.
3.
4.
5.
6.
DRY ZONE
SAUNA STEAM ZONE
1.
CONTROL PANEL
2.
DATA CABLE (supplied by the installer)
3.
POWER UNIT
4.
DOOR SENSOR
5.
TEMPERATURE SENSOR
6.
HEATER (sold separately)
min 4 x 0.34 mm
2
min 4 x 0.34 mm
2
min 2 x 0.34 mm
2