Dual 20 Amp Relay Companion Module - QRG | 009-2129-00
1 of 4
45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220408
120V 20A DU
AL RELA
Y
GPM-C2R20
120
MODULE INPUT
:
LOAD INPUT
:
LOAD OUTPUT
:
INDOOR USE ONL
Y
#12-8 A
WG Cu ONL
Y
HOME A
UTOMA
TION EQUIP
IC ID: 10
798A
-QP2R20
120
FCC ID: PUU-QP2R20
120
EXXXXXX
YYW
W
120V
AC 20A/
1HP MA
X/CHAN
RES, MO
TOR
120V
AC 60Hz
120V
AC 60Hz
LOAD TYPE:
INPUT
OUTPUT
A
A
INPUT
OUTPUT
B
B
PAIR
DO NO
T
PRES
S ON
SCREEN
REMO
VE AFTER
INST
ALLA
TION
CIRCUIT PO
WER
B
A
A
B
C
E
F
G
D
A
Multi-Page LCD screen that can display the following:
–
Power draw and energy usage at each output.
–
Firmware, Mac Address, and Regulatory Info.
–
UID of the Host that the module is communicating with.
–
Real-time Bluetooth status connectivity icon.
B
Manual Load Switches
- Toggle to the ON position to switch
the load on. Toggle to AUTO for normal operation. Switch A
controls output A, Switch B controls output B.
C
PAIR Button
- The PAIR button is a multi-use button. The
duration that the button is pressed and held determines the
function that gets initiated:
Press and Release
- Cycles through the screens available on
the LCD (POWER > ENERGY > INFO 1 > INFO 2).
Press and hold
- Press and hold for 2 second to put the
module into pairing mode. Press and hold for 5 seconds to
reset.
D
Input Power Connections
- Connect the outputs from two
feeder breakers to inputs A and B on the module. See the
section below.
E
Output Power Connections
- Connect output A and output B
to separate loads. See the
F
120V AC Connection
- Plugs into the 120V AC bus bar in the
breaker panel. The voltage on this connection powers the
module.
G
Neutral
- The model number of the Companion Module
determines the type of neutral connection available:
– Plug-On Neutral
- Positioned on the bottom of the module
is a neutral clip that plugs directly onto the neutral bar.
– Pigtail Neutral
- A neutral wire protrudes from the
module’s rear and gets wired to the neutral bar in the
breaker panel.
Minimum Supported Release
Savant OS
da Vinci 10.1
Electrical and Safety Characteristics
Screw Tighten Torque
3.0 Nm
Wire Type
Copper (Cu) only
Pollution Degree
2
Purpose of Control
Operating Control, Smart Relay Control
Module or equivalent
Software
Class A
Impulse Voltage
2500V
Supported Load Types
Standard Configuration Relay On/Off type loads
(home automation)
Standards
Wireless
Bluetooth 5 Low Energy (BLE)
–
2.4 GHz radio frequency
Regulatory
Safety and Emissions
FCC Part 15
UL
ICES 003
Contains FCC ID:
PUU-QP2R20120
Contains IC:
10798A-QP2R20120
RoHS
Compliant
Recommended Load Center Types
All Eaton CH style modules fit into a
¾
inch Eaton CH load center.
Power
Input Power
(powers the module)
120V AC (+/- 10%) @ 60 Hz, 0.1A (max)
Input Power
(from feeder breaker)
120V AC @ max power load
Load Power
2400VA max per channel
(20A resistive load / 1 HP max per channel)
Features of Automatic
Action
Type 1.B action
Dimensions and Weights
Length
Width
Height
Weight
Module
4.96 inch
(12.6 cm)
1.46 inch
(3.7 cm)
3.39 inch
(8.61 cm)
.54 lbs
(.24 kg)
Shipping
7.48 inch
(19.0 cm)
4.17 inch
(10.60 cm)
1.69 inch
(4.29 cm)
1.0 lbs.
(.45 kg)
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
5% to 85% Relative Humidity (non-condensing)
Location
Indoor Use Only
Features
–
Control capability for loads up to 2400VA per channel.
–
All Eaton CH style relay modules are compatible with Eaton CH
3/4
inch load centers.
–
Dynamic management of loads.
–
Built-in energy monitoring; +/- .5% revenue grade accuracy / 1 sec
sample time.
–
Communicates over the air using Bluetooth Low Energy (BLE)
technology.
–
Manual load switches, available on the front panel, can toggle
power to the outputs On and Off.
–
Color LCD display for easy identification and load status.
Dual 20 Amp Relay Companion Module (120V AC)
(Supports Eaton CH Load Centers)
Quick Reference and Installation Guide
Specifications
Box Contents
Descriptions
(1) Dual 20 Amp Relay Companion Module (Eaton CH)
–
GPM-CP2R20120-21 w/Plug-on Neutral
-or-
–
GPM-C2R20120-21 w/Pigtail
(1) Product Information and Regulatory Insert (009-1950)
(1) Quick Reference and Installation Guide (this document)
Construction of Control
Open Type
Independently mounted for flush mounting