PAV-SIPA125SM-05 | 009-1657-03 | 200709
© 2020 Savant Systems, Inc.
45 Perseverance Way, Hyannis, MA 02601
Savant.com
| 508.683.2500
(1) IP Audio 125 (PAV-SIPA125SM-05)
(1) Install Kit (075-0202-xx)
(1) Power Cord (064-0431-xx)
(2) 2U Chassis mounting ears (071-0113-xx)
(4) M5X12mm Screws (039-0034-xx)
(4) 4-pin Speaker connector (028-0702-xx)
(2) 6-pin Control connector (008-0664-xx)
(2) 3-pin Control connector (028-0665-xx)
(1) Product Information and Regulatory Statement (009-1950-xx)
Box Contents
Specifications
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Maximum BTU
1750 BTU/HR
Dimensions
Height
3.46 in (87.9 mm)
Width
17.30 in (439.4 mm)
Depth
14.24 in (361.8 mm)
Weight
14.3 lb (6.5 kg)
Rack Space
2U
Power
Input Power
100/240V AC (50/60 Hz) 5.7A
Maximum Power
515W
Operating Parameters
Rated Power
(Speaker
Output)
125 WPC at 8 ohms (THD+N < 0.1%)
Frequency
Response
20 Hz - 20 kHz +/- 0.5 dB, speaker output
Signal-to-Noise
Ratio (SNR)
>100 dB, speaker output
Supported
Digital Input
Formats
44.1 kHz / 48 kHz / 96 kHz at 16-bit / 20-bit /
24-bit resolution
Networking
Supported
Standard
IEEE 802.1 AVB/TSN switches
IEEE 802.3 Ethernet
Regulatory
Safety and
Emissions
FCC Part 15B
CE Mark
C-Tick
UL
RoHS
Compliant
Minimum Support Requirements
Software
Release
da Vinci 9.0.2
Music Streaming
The Savant IP Audio has a built-in single stream of Savant Music.
(Streaming service fees may apply.)
Front Panel
Reset
Hold Reset Button for 5 seconds while powered
On to clear network settings. Status LED will
rapidly blink red when reset is complete.
On/Off
On
: Fully enables all internal power rails and
processor.
Off
: Disables internal power rails and processor,
but not internal AC/DC power supply. To fully
power off unit, press the I/O power switch on the
rear panel to Off [O].
Standby Mode:
Hold On/Off button for about 5
seconds. Hold On/Off button for about 1 second
to take system out of standby mode. The I/O
power switch on the back of unit must be On (I)
to enable this function.
Power LED
Green
: System has power and is operating
normally.
Red
: System is in standby mode and most of the
controller circuitry is powered down.
Off
: System is not receiving power.
Status LED
Green Blinking
: Embedded system is ready, but
no communication has been established with the
host.
Green
: Host has established communications with
the embedded system.
Red Blinking
: Embedded firmware is running, but
has not received a DHCP IP Address.
Red
: Host has determined the firmware needs to
be updated, but a problem occurred during the
process that will initiate a reset.
Amber Blinking
: Embedded system has a valid
link local IP Address and is connecting to the
host.
Amber
: Host is updating the embedded
firmware.
Off
: Embedded processor is resetting, or is
powered up, and is booting the embedded
firmware.
Hardware Failure
: If hardware failure occurs,
the status LED will be interrupted every three
seconds with a solid red indication.
Relay LED
Green
: Relay port activity.
Off
: No Relay port activity.
GPIO LED
Green
: GPIO port activity.
Off
: No GPIO port activity.
Zone Status
Green
: Zone in use.
Red
: Protection mode has been enabled to
protect a zone/channel; typically indicates
thermal protection, clipping or over current.
Off
: Zone is off and protection mode has not
been enabled.
A
B
C
D
E
F
G
G
F
E
D
C
B
A
IP Audio
GPIO
Status
Relay
4
3
2
Zone Status
Power
Reset
1
On/Off
Savant® IP Audio 125 with Savant Music 2.0 [PAV-SIPA125SM-05]
Quick Reference Guide