Bind using the UID Field
Establishing the bindings using the UID field in RacePoint Blueprint is described below. This process is
typically used if the Bind/Un-Bind button process described above does not work. This process manually
enters the UID into the configuration running in RacePoint Blueprint.
Prior to starting the process, the user must obtain the UID of the Lamp Control. To get the UID, the
SmartConnect application must be used. Open the SmartConnect application and copy the UID of the
Lamp Control. Refer to
Provisioning Steps – SmartConnect
for information on getting the UID.
1.
Verify sections 8.1 through 8.5 above are completed.
2.
From the Lighting/Keypad Manager, select the
Keypads
tab (see image below).
3.
Select the Lamp Control from the list of lighting devices (see image below).
4.
Double-click the UID field and enter the UID of the Lamp Control (see image below)
5.
Repeat steps 3 and 4 above and add the UID to the UID field of all the Lamp Controls in the lighting
devices list Close Lighting and Keypad Manager when done.