Savant Lamp Control Deployment Guide
Copyright © 2016 Savant Systems, LLC
009-1388-01 | 160810
7
of
38
4.
Connections
Prior to configuring the Lamp Control into RacePoint Blueprint, it can be connected and tested to verify the
lamp can be toggled on and off.
1.
Plug the Lamp Control directly into an overcurrent protected 120V AC receptacle/outlet.
2.
Plug the cord from a lamp into the receptacle on the Lamp Control. Turn the Lamp Switch to the On
position.
3.
Verify the LED on the side of the Lamp control is blinking yellow (factory default setting). See
Blinks Once
(Yellow)
section below.
Blinking yellow indicates the Lamp Control is in Access Point
Provisioning Mode. This is how the Lamp Control is configured
when leaving the factory. If it is not blinking yellow, press and
hold the reset button for 5 seconds until the LED blinks red then
release. See
Rapid Blink (red)
.
4.
Press and release the reset button positioned on the bottom of the Lamp Control. Verify the lamp/load
toggles On and Off. The Lamp Control is now ready to be provisioned.