2.1.3 Installing the PoE Cable to the RSU
An exploded view is shown in [Figure 9]. To install the sealing gland to the Ethernet port
of the RSU, follow the steps:
1. Ensure that you have an unterminated Ethernet cable from the PoE/cabinet to the
RSU. For optimal function, the diameter of the Ethernet cable must be between
<limits?>
Loosen the round end of the sealing gland kit by turning counter clockwise (but do
not remove the round end). The thread end is towards the right and the round end
towards the left in
3. Insert the unterminated end of the Ethernet cable into the round end of the sealing
gland and pull several inches of cable through the adaptor. The cable should have
passed through the seal and the body housing.
4. Install an RJ-45 connector to the unterminated end of the Ethernet cable using an
appropriate installation RJ-45 crimping tool.
5. Insert the RJ-45 cable connector into the Ethernet port receptacle of the RSU and
ensure that the RJ-45 is locked into the internal RJ45 jack.
6. Slide the sealing gland kit towards the RSU and screw the threaded end into the
RSU and hand-tighten.