12
M2LIFT Owner’s Manual
Part No. 001103, 28-m08-2018
Maintenance Schedule
Verification by owner
Frequency
Verify general operation of the lift
Every 2 months
Verify correct operation of the safety devices:
• Underpan sensors
• Emergency stop
• Gate lock (the lift should not run unless the gate is closed
and locked)
Every 2 months
Verification by technician ONLY
Frequency
Verify the following:
• General operation of the lift
• Operation of the underpan sensors
• Operation of the emergency stop
• Operation of the gate lock contacts. The lift should not
run unless the gate is closed and locked.
Every 6 months
Check the suspension system:
• Chains
• Connecting links
• Chain pulleys and shafts
• Parts holding the chains on the roller supports
• Chain tensioners on the rail (they should be tight)
Every 6 months
Verify that all hardware is tightened.
Every 6 months
Check the safety brake.
Every 6 months
Check the rollers (function and wear).
Every 6 months
Ensure that all filler panels are securely fastened in the gate.