Manual Operation in an Emergency
You can use manual operation to bring the lift to the next landing in the event
of a power failure or equipment breakdown.
Before proceeding with manual operation, you MUST
switch off the main power switch on the external control
box.
Moving the Lift in an Emergency
1
Switch off the main power switch on the external control box.
2
Push back the small lever protruding from the handwheel access hole in the
bottom of the drive unit cover. Install the handwheel on the motor shaft
(see Figure 10 below). NOTE that you can also use an electric drill with the
provided adapter for faster lowering.
3
Push down and hold the brake release lever. Turn the handwheel in the
desired direction until the closest landing has been reached. Note that this
process is very slow.
4
Release the brake lever and remove the handwheel. Store the handwheel in
an easily accessible place.
Figure 10
WARNING
Handwheel
Brake release lever